Omron E2E-X7D1-N1: Discontinued, for Sustaining Builds

E2E-X7D1-N1 Omron product image

7mm sensing, 10V ~ 30V supply, M18 thread; not for new design-in.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 7MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V

Discontinued status confines this sensor to existing production

Don't design it in. E2E-X7D1-N1 carries EOL and Discontinued labels; either way, plan material for existing production and start migration. EU RoHS compliance does not change that call.

The supply and temperature limits bound the installation

The supply and ambient limits constrain where the sensor can run. Its listed 10V ~ 30V supply range rules out a rail below 10V; 30V is the upper ceiling, not a working target. The -25°C ~ 70°C operating range excludes colder locations, and 70°C is the upper ambient ceiling at the mounting point. Neither range establishes behavior at a particular target distance.

A 7mm reach has to work with the M18 mount

7mm is the listed sensing distance. If the target cannot stay within that reach through its travel and mounting tolerance, the shielded, threaded cylindrical body's M18 mount cannot make up for the gap. The body belongs in a mounted industrial fixture with a route for its cable leads, not a hole made for a different thread.

NPN-NO, 2-wire output must match the controller input and wiring scheme; an input expecting another output arrangement is not a direct connection. The listed 500Hz response frequency helps screen event rates but does not specify switching delay for fast-moving targets. IP67 rates the sensor's ingress protection, not the sealing of the machine's cable connection.

The wiring and target behavior still need drawings and curves

That still leaves the wiring diagram absent: the NPN-NO, 2-wire label does not identify the leads or settle the input connection. Without a mounting drawing, M18 identifies the thread but not body length or cable-exit clearance. Target-dependent sensing characteristics and switching delay are also absent, leaving the checks behind the 7mm reach and 500Hz response frequency unresolved.

View the Win-Source product page for E2E-X7D1-N1.

Key Takeaways for Engineers & Buyers

  • Block E2E-X7D1-N1 from new designs; plan migration for existing production.
  • Check 7mm reach against target travel before committing the M18 mount.
  • Match the 10V ~ 30V supply range and NPN-NO, 2-wire input scheme.