Omron E2E-X7D1S: Active for new machine designs

E2E-X7D1S Omron product image

7mm sensing limit, 10V ~ 30V supply, threaded M18 body and cable leads

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 7MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 30V

The 7mm limit makes the target test decisive

7mm is the listed sensing-distance ceiling, not a guaranteed trip point for every metal target. At 500Hz, the stated response frequency sets a switching-speed ceiling, but it doesn't establish detection of every moving target, so test the actual target and approach before fixing the sensor position. The 10V ~ 30V supply span is the operating range, not a nominal rail; a control circuit outside that range rules the sensor out.

The NPN-NO, 2-wire output makes controller-input compatibility a design-in decision. An input built for a different output arrangement cannot be assumed to read it correctly.

Can this active sensor stay on the line?

Is this sensor still Active? Yes. Lifecycle and product status agree, supporting new design-in and existing production. Specify handling for the bulk packaging and cable leads before line release. It is EU RoHS compliant.

The M18 body belongs on the machine, not the board

That leaves the physical fit. The threaded M18 cylinder and cable leads need mounting space and a cable route; this is a machine-mounted inductive sensor, not a board-level part. IP67 supports an exposed mounting position but does not establish protection for the cable termination. The -25°C ~ 70°C operating-temperature span sets the site boundary: outside it, the installation fails the stated environmental range even if the target is detectable.

The missing cable diagram still blocks sign-off

The cable wiring diagram is missing, despite the stated 2-wire output. The output label alone cannot settle the input circuit, and the absent output load-current rating leaves the controller-input match open. Get the mounting drawing before committing clearance around the threaded body and cable. Target-material sensing curves are missing too; the 7mm ceiling cannot establish the switching gap for the actual target.

View the Win-Source product page for E2E-X7D1S.

Key Takeaways for Engineers & Buyers

  • Test the actual metal target against the 7mm sensing-distance ceiling.
  • Keep the sensor supply within the listed 10V ~ 30V operating span.
  • Reserve mounting space for the threaded M18 body and cable leads.