10V ~ 30V supply, 10mm sensing, M30 threaded body, -25°C ~ 70°C ceiling for existing production only
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Bulk |
| Core function | SENSOR PROX |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NC, 2-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
10V ~ 30V is usable, but the lifecycle kills new design-in
10V ~ 30V is the supply window, but it does not rescue this part for a new program. The lifecycle calls do that, and here they land on EOL and Discontinued. That makes this a sustaining-only sensor.
The basic fit is clear enough: inductive sensing, NC 2-wire output, shielded construction, and a Cylinder, Threaded - M30 body. EU RoHS status is still unresolved because one field says compliant and another says non-compliant.
Can you actually buy enough to keep a line moving?
Can you get enough parts to matter? Probably not.
Listed stock is 1, and the part comes in Bulk, so availability is the real constraint. A single unit is useful for a field failure or a stopped station on an existing machine, not for any forward build. Hold that unit for service demand, then remove E2E2-X10D2 2M from the next build plan.
Fit is narrow
Use it sparingly.
E2E2-X10D2 2M fits existing industrial proximity installs where the M30 threaded brass body, cable leads, and IP67 already match the hardware.
The listed numbers set fit, not performance margin
The weak point is missing detail. The strong point is that the numbers here still define where E2E2-X10D2 2M fits.
The 0.394" (10mm) sensing distance fixes the mechanical target zone, so a bracket, guard, or flag laid out around that reach stays in bounds. What you do not get is switching margin against target material variation, because that curve is absent.
The 400Hz response frequency is a ceiling, not proof that every installation will switch cleanly at that rate, and the -25°C ~ 70°C operating temperature range is a ceiling as well. That points to ordinary indoor industrial ambient, while hotter enclosures or cold-soak exposure beyond those limits are out.
Package and termination narrow the fit further. A Cylinder, Threaded - M30 body with Cable Leads belongs on equipment that already expects a large threaded barrel, and it is a much less natural choice where dense sensor clusters or connectorized service loops drive the layout.
The remaining gaps are concrete and important: no pinout detail beyond NC, 2-Wire, no drawing, no load current figure, and no switching hysteresis or repeatability data. Those missing items decide whether E2E2-X10D2 2M drops into an existing circuit without surprises.
View the Win-Source product page for E2E2-X10D2 2M.
Key Takeaways for Engineers & Buyers
- Lock any open build to the 10V ~ 30V supply window before touching the sensor BOM.
- Reserve the single listed unit only for line-down support on E2E2-X10D2 2M.
- Resolve the RoHS conflict before shipment; one field says compliant and another says non-compliant.