10V ~ 30V supply, 10mm inductive range, M30 threaded body, -25°C ~ 70°C ceiling
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 2-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Can you still buy E2E2-X10D2 with confidence?
Can you count on supply here? No. Lifecycle is Discontinued, the notes also show an EOL signal, and available quantity is 0.
That settles the new-design question fast. For an existing production line, the practical move is a controlled last-need buy against real demand while you remove E2E2-X10D2 from future releases. EU RoHS compliance is still listed, but it does not change the lifecycle stop.
10V ~ 30V sets the rail window, not the load behavior
10V ~ 30V is the first number that decides fit. It sets the supply window for the machine rail and rules out any design that expects operation below 10V or above 30V.
The next hard check is 0.394" (10mm) sensing distance. That number drives target geometry, bracket tolerance, and metal approach, and if it misses the stackup the failure mode is straightforward missed detection rather than some vague analog drift. Response frequency is 400Hz, so treat that as the event-rate ceiling when target speed or pulse density starts to climb.
Mechanical details matter just as much. The Cylinder, Threaded - M30 body in nickel-plated brass points to a large panel-mounted sensor, while IP67 places it in dirty industrial areas and washdown exposure rather than open electronics.
The weak point is supply, but the mechanical fit is clear
Availability is the problem, not the physical role. This is a shielded inductive proximity sensor with cable leads, an LED indicator, and an M30 threaded body for straightforward machine mounting.
Wrong for dense fixtures, right for blunt industrial detection
Wrong for compact sensor arrays, tight brackets, or any build that cannot spare an M30 threaded cylinder and cable-lead exit. It is also wrong when the control side expects a different switching arrangement, because NPN-NC, 2-Wire is not something you patch later in panel wiring.
It fits simple metal target detection on 10V ~ 30V rails where 10mm sensing is the requirement and IP67 matters. The shielded construction helps when you need a defined sensing face in crowded metalwork, and the -25°C ~ 70°C operating temperature range is the ambient limit for the installation, not a blanket answer for every mounting condition inside that span.
The real review blocker is what the listing leaves out
The constraint is missing detail. The listed numbers are enough to place this sensor in the right product class, but they are not enough to close a serious release because the remaining gaps affect wiring, mounting, and timing margins under real plant conditions.
Start with the pinout or lead assignment. For a cable-lead, NPN-NC, 2-Wire device, that omission stops panel integration because the installer still needs conductor function, not just output style.
Then there is the mechanical drawing beyond the M30 callout. Thread length, body length, and sensing-face geometry determine bracket design, locknut stack, and clearance, and those dimensions decide whether the sensor actually fits the machine rather than merely sounding compatible in a summary line.
Switching detail is thin too. The 400Hz figure is only a ceiling; there is no timing breakdown, no load information, and no current figure for the output path, so control-input compatibility remains open.
Mounting guidance tied to the shielded construction and 10mm sensing distance is also absent. Without that, flush-mount assumptions and target spacing remain assumptions.
View the Win-Source product page for E2E2-X10D2.
Key Takeaways for Engineers & Buyers
- Block new BOM releases on E2E2-X10D2; lifecycle is Discontinued and stock is 0.
- Check the control input against NPN-NC, 2-Wire before touching panel wiring.
- Reserve M30 mechanical space only if the 10mm sensing distance fits the target stackup.