Omron E2E2-X10Y1-M4 active for new design-in

E2E2-X10Y1-M4 Omron product image

20 VAC to 264 VAC, 10 mm sensing, M30 threaded body, -40°C to 85°C, 25 Hz response

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC
Reported stock1 pcs reported — confirm on RFQ

20 VAC to 264 VAC decides the application

20 VAC to 264 VAC is the deciding number here. It puts this sensor on AC-powered industrial sensing points and rules it out for a low-voltage DC sensor rail before anything else is considered.

The rest of the listing stays consistent with that read. The output is SCR-NO, 2-Wire, so this is not a generic three-wire proximity switch you can drop into any PLC input card without checking the input method first. Active lifecycle and EU RoHS support new design-in. Stock does not: quantity is 1, so treat it as a qualification sample or a stopgap buy rather than a production answer.

And 25 Hz is a hard speed ceiling

And 25 Hz matters more than the LED or the nickel-plated brass body, because it sets the maximum event rate the sensor can follow before missed detections become a machine problem. It is a ceiling, not a timing-margin guarantee across every target and mounting condition.

The 0.394" (10mm) sensing distance is the other limit that drives placement. It defines the detection envelope, but not the tolerance stack around target material, approach direction, or hysteresis, because those details are not shown here. Shielded construction helps in tighter metalwork, though the mounting drawing is still missing.

Wrong for fast indexing, right for AC machine sensing

Wrong for high-speed counting. Right for slower position confirmation, presence checks, and end-of-travel detection on AC-powered equipment, especially where an M30 threaded cylinder already fits the machine.

The package narrows the fit further. Cylinder, Threaded - M30 with connector termination works well in industrial panels and machine frames, but not where space is tight or where the control architecture expects compact low-voltage DC prox sensors. E2E2-X10Y1-M4 fits jobs where rugged mounting, IP67 sealing, and AC supply compatibility matter more than switching speed.

Can you actually buy it now?

Can you get one now? Barely. Listed stock is 1, so use it for bench work or a line-down spare and hold any production release until availability improves.

The missing details are the ones that close the review

Key details are missing.

Several practical decisions stay open because the listing stops short of the electrical and mechanical specifics that usually decide sensor interchangeability. There is no pinout or connector wiring detail, so input-card mapping cannot be finished from this page. There is no dimensional drawing beyond M30 and no mounting geometry, so bracket layout and clearance checks remain open as well.

The output is identified as SCR-NO, 2-Wire, but there is no load current figure, no leakage detail, and no voltage drop figure. Those are the values that determine whether a PLC input sees a clean OFF state and whether a marginal AC input chatters in the field. E2E2-X10Y1-M4 may still be the right sensor, but this is where the integration risk sits.

Some limits are at least clear. Operating temperature is -40°C to 85°C, and sealing is IP67. That sets the environmental ceiling, but not the whole installation picture; cable orientation, target requirements, and mounting constraints still need the full datasheet.

View the Win-Source product page for E2E2-X10Y1-M4.

Key Takeaways for Engineers & Buyers

  • Match E2E2-X10Y1-M4 only to 20 VAC to 264 VAC control power.
  • Reserve panel space for the threaded M30 body and connector exit.
  • Do not use E2E2-X10Y1-M4 where the target event rate exceeds 25 Hz.