20 VAC ~ 264 VAC, 25Hz, 10mm shielded M30 inductive sensor, -40°C ~ 85°C, SCR-NO 2-wire output
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
| Reported stock | 1 pcs reported — confirm on RFQ |
Active status helps, but stock does not
Use it.
Lifecycle is the easy part here: Active, with no conflict between status fields, so there is no hidden NRND or end-of-life warning in the record. EU RoHS is clear as well.
Availability is the problem. Stock is 1, which makes E2E2-X10Y1-US a reasonable design-in only when the build plan is real. Put it on the BOM if the electrical fit is right, but don't assume this listing alone covers near-term production.
The real limit is speed, then the line voltage window
The constraint is machine timing first, interface second. A 25Hz response ceiling puts this sensor in slow presence-detection work, not in jobs where a target moves quickly or where the controller expects tight event timing. Miss that distinction and the failure mode is familiar: detections drop out in the field, look intermittent, and waste time before anyone traces the problem back to a sensor that was never meant to switch that fast.
The 20 VAC ~ 264 VAC supply range is the next gate. Treat it as a supply ceiling and floor, not as proof that every control input will behave well across that span, because the listing says nothing about current draw, off-state leakage, or how a specific PLC input will interpret the output. What it does settle is the basic architecture question: E2E2-X10Y1-US belongs on AC sensing circuits, not on low-voltage DC sensor rails.
Output style closes the loop. SCR-NO, 2-Wire is not just another way to say transistor output; it commits the design to a two-wire AC switching scheme, which rules out plenty of DC input cards and any casual dry-contact assumption. The 0.394" (10mm) sensing distance matters, but only after speed, supply, and output type already fit the machine.
10mm and M30 tell you where it belongs
10mm is the key figure. That 0.394" sensing distance, paired with a shielded body and a Cylinder, Threaded - M30 package, points E2E2-X10Y1-US toward measured machine positions where a larger threaded sensor is useful and the target does not need to be picked up at speed.
That makes it a sensible fit for end-of-stroke confirmation, gate or fixture presence, and metal target detection where 25Hz is enough. On the environmental side, the listing is stronger than the control-side detail: IP67 plus NEMA 1,4,6,12,13, a Nickel-Plated Brass body, and an operating range of -40°C ~ 85°C support use in dirty industrial mounting points or washdown-adjacent areas. Those are still environmental ceilings, not proof against every chemical exposure, cable-flex pattern, or thermal-cycling profile. Cable Leads also push it toward fixed machine wiring rather than quick-swap sensor blocks.
What the listing still doesn't answer
Weak point first: the interface detail is thin.
The listing gives enough to classify E2E2-X10Y1-US correctly, but not enough to finish the control-side review. The missing items that matter are lead wiring or pinout, the mechanical drawing beyond "Cylinder, Threaded - M30," and the output electrical details that usually decide PLC compatibility for a 2-wire SCR sensor, especially leakage and load requirements. It also stops at a 25Hz response figure, so there is no switching curve or added timing detail here to judge edge behavior.
View the Win-Source product page for E2E2-X10Y1-US.
Key Takeaways for Engineers & Buyers
- Match the control circuit to SCR-NO, 2-wire output before releasing E2E2-X10Y1-US.
- Check machine timing against the 25Hz response ceiling; this sensor is for slow position presence, not fast counting.
- Buy only against demand now; stock is 1 and the package is Bulk.