Omron E2E2-X10Y1 active, but buy only for planned builds

E2E2-X10Y1 Omron product image

20 VAC to 264 VAC, 10 mm inductive range, M30 body, -40°C to 85°C limits the fit

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC
Reported stock0 pcs reported — confirm on RFQ

Still, this is a real AC sensor, not a low-voltage add-on

And that 20 VAC to 264 VAC supply range is the first real filter. It rules out low-voltage DC sensor slots and points instead to mains-adjacent industrial sensing where a 2-wire SCR-NO output is expected, but it still leaves key interface behavior unanswered, including load current, leakage, and exactly what the input card sees when the sensor is off.

The rest follows from there. A 0.394" (10mm) sensing distance in a shielded inductive head points to short, controlled metal detection rather than long-standoff presence sensing, while the Cylinder, Threaded - M30 package buys mounting stability and mechanical presence, not a discreet fit inside a cramped bracket.

The constraint is mechanical and electrical fit at once

The constraint is fit, in both senses. The M30 threaded body sets the mechanical boundary first: bracket size, panel clearance, and cable routing all get decided before the sensing job does. If the machine already expects smaller barrels or flush mounting in tight steelwork, this body size breaks the fit early.

Electrical fit is just as restrictive. The supply ceiling is 264 VAC, with a listed range of 20 VAC to 264 VAC, and the output is SCR-NO, 2-Wire. That combination is common enough, but it does not settle compatibility with a PLC input, relay coil, or indicator circuit on its own, because the missing load and off-state leakage figures are what determine whether the interface switches cleanly or chatters at the edge. Get that wrong and the symptom is obvious: the target is present, the LED says so, and the control input still misreads.

Response speed is the other hard limit. At 25Hz, this sensor fits slower position confirmation and machine-state sensing. It does not fit faster counting or motion feedback jobs where target events stack up faster than the sensor can report them.

Environmental ratings help, but they don't rescue a bad interface choice. The -40°C to 85°C operating temperature and IP67 ingress protection make it credible for outdoor or washdown-adjacent equipment, and the nickel-plated brass body points to a conventional industrial mechanical build rather than a lightweight embedded assembly.

The weak point is supply, not lifecycle

Zero stock is the weak point. Active lifecycle status and EU RoHS compliance are both clean, so it remains reasonable for new design-in or sustaining builds if you can buy to a schedule rather than cover an immediate shortage.

The datasheet gaps are the real review blockers

These gaps matter.

There is no load current figure for the SCR-NO, 2-Wire output, no off-state leakage figure, and no wiring or pinout detail beyond cable leads. For an AC proximity sensor, those are the items that decide whether it will switch the intended input cleanly or leave you chasing false states in commissioning.

The mechanical drawing is missing too. The listing gives M30 and a 10 mm sensing distance, but not the body length, thread length, or mounting geometry needed to close the bracket design.

View the Win-Source product page for E2E2-X10Y1.

Key Takeaways for Engineers & Buyers

  • Match the control rail to 20 VAC to 264 VAC before placing E2E2-X10Y1 on the BOM.
  • Reserve panel space for a threaded M30 body; this is not a small-barrel sensor.
  • Treat listed stock of 0 as a scheduling issue and line up supply before release.