10V to 55V supply, 18mm sensing, M30 body, and -40°C to 85°C limits define the remaining fit
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 18MM CYL |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 55V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Discontinued is the problem, not the sensing spec
The weak point comes first: E2E2-X18MB1-M1 is discontinued, and the lifecycle conflict does not change the outcome. One field says EOL and two say Discontinued, so it is out for new design-in and only defensible in existing production that already depends on it.
The usable case is much narrower. If a running machine already expects an inductive, unshielded, PNP-NO 3-Wire sensor with 0.709" (18mm) sensing distance, an M30 threaded body, connector termination, and a 10V ~ 55V supply ceiling, this part can still serve as a line-keep component. The listed -40°C ~ 85°C operating temperature and IP67 ingress protection place it on industrial equipment rather than in a cabinet-only installation, and EU RoHS compliance removes one more question from sustainment work. Still, none of that rescues the lifecycle, and with stock at 1 the practical move is to hold it for sustaining demand, keep it out of any fresh release, and start the migration now.
The 10V to 55V rail is a fit check, not a comfort blanket
So the supply range only gets you through the first gate. The 10V ~ 55V figure tells you whether the machine rail belongs in the conversation at all; it does not answer noise margin, output loading, or startup behavior, because those numbers are not here.
The other hard limit is the 100Hz response frequency. That is a ceiling, not an operating target, so E2E2-X18MB1-M1 fits position presence and slower target detection but should not be treated as cleared for fast counting or tight timing where missed edges turn into field faults. Pair that with the 0.709" (18mm) sensing distance, unshielded construction, and Cylinder, Threaded - M30 package, and the mechanical layout starts to matter as much as the electrical fit, because mounting geometry can shift the installed trip point away from the nominal number.
Best in exposed machine sensing, wrong for dense fixtures
Mounting space is the real constraint. A Cylinder, Threaded - M30 body in nickel-plated brass suits industrial hardware that can spare the diameter and wants a durable threaded mount, not dense fixtures where every millimeter around the sensing face is contested.
That geometry, along with connector termination and LED indication, works well on conveyors, guards, and general machine stations where replacement speed matters and local visual status helps. The unshielded build pushes it away from tightly packed metalwork. The 18mm sensing distance helps with stand-off, but it does not excuse careless bracket design.
What the listing still does not answer
Wrong for final signoff. Fine for a quick sustainment call.
The missing items are concrete: connector pinout, a mechanical drawing for the M30 body and sensing face, load current or output electrical limits for the PNP-NO 3-Wire output, and switching detail beyond the 100Hz ceiling.
View the Win-Source product page for E2E2-X18MB1-M1.
Key Takeaways for Engineers & Buyers
- Freeze E2E2-X18MB1-M1 to existing builds only; lifecycle is Discontinued.
- Check the controller input against PNP-NO, 3-Wire before touching the BOM.
- Reserve the single listed unit for line-down service, not qualification work.