Omron E2E2-X18MY1-US 5M is fit for new design-in

E2E2-X18MY1-US 5M Omron product image

20 VAC to 264 VAC supply, 18 mm sensing, M30 unshielded body, -40°C to 85°C limits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 18MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC
Reported stock0 pcs reported — confirm on RFQ

264 VAC is the first gate, not the 18 mm range

264 VAC comes first. The listed supply is 20 VAC to 264 VAC, and that ceiling decides whether this sensor belongs on the schematic before the 0.709" (18mm) sensing distance matters at all.

That supply window tells you one thing clearly: this is an AC-powered proximity sensor, not a low-voltage DC input device. The 18 mm sensing distance and unshielded M30 threaded body then narrow the mechanical fit. This points to generous detection space rather than tight flush mounting near surrounding metal, and if that assumption is wrong, the field problem is nuisance trips or missed targets rather than a small calibration tweak.

For industrial AC sensing, E2E2-X18MY1-US 5M is a credible new design-in option. EU RoHS is straightforward. The mechanical envelope still has to be real in the assembly.

Wrong for fast machine timing, right for slow AC presence sensing

Not for high-speed counting. The listed response frequency is 25Hz, and that ceiling rules out applications where target events arrive quickly or where control logic depends on short detection windows.

It does fit slower industrial presence detection on AC-powered equipment, especially where the environment is dirty enough to justify IP67 and the NEMA 1,4,6,12,13 enclosure claims. The -40°C to 85°C operating temperature range gives useful plant-floor headroom, but it does not answer self-heating, mounting derating, or cable-temperature behavior. The SCR-NO, 2-wire output narrows the fit further: use it where a normally open AC sensor output is expected, not where the control input was drawn around a DC transistor sensor.

And the buy problem is simpler than the fit problem

And that leaves the easier problem: availability. Active status helps, but stock quantity is 0, so the constraint here is line timing rather than lifecycle risk. If this sensor is already qualified in your build, place a scheduled order against demand instead of assuming spot availability.

The missing numbers are the ones that close the review

The constraint is missing electrical detail. The broad fit numbers are here, but the values that settle interface risk on an AC input chain are not.

There is no load current figure for the SCR-NO, 2-wire output, no off-state leakage, and no voltage drop across the output. Those numbers decide whether a PLC input releases cleanly, whether a relay chatters, and whether a supposedly compatible AC input sits half-on in the field. The listing also omits cable details beyond Cable Leads, so the 5M suffix appears in the part number without a cable specification here.

Mechanical closure is incomplete too. You get Cylinder, Threaded - M30 and unshielded, but no drawing, no pinout-equivalent wiring detail, and no mounting dimensions beyond the thread family. That is where panel spacing and bracket design stop being assumptions and become released hardware.

View the Win-Source product page for E2E2-X18MY1-US 5M.

Key Takeaways for Engineers & Buyers

  • Match the input rail to the listed 20 VAC to 264 VAC supply window before releasing E2E2-X18MY1-US 5M.
  • Reserve M30 threaded mounting and clearance for the 18 mm unshielded sensing geometry.
  • Place a scheduled buy against demand now; stock quantity is 0 even though E2E2-X18MY1-US 5M is Active.