10V to 30V supply, 20mm sensing, M30 body, -25°C to 70°C, 100Hz response
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Bulk |
| Core function | SENSOR PROX |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NC, 2-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
20mm sensing does not outweigh the stop-ship lifecycle
20mm is the headline spec, but it does not change the sourcing call. E2E2-X20MD2 2M is discontinued, and the lifecycle fields conflict between EOL and Discontinued without supporting any active status, so the conservative decision is clear: no new design-in, sustaining use only. EU RoHS is not settled either, because one field marks the part compliant while another marks it non-compliant.
When it was current, the listing placed E2E2-X20MD2 2M in a familiar machine-sensing slot: an inductive proximity sensor with unshielded construction, a threaded M30 cylinder, cable leads, NC 2-wire output, LED indication, and IP67 ingress protection. That points to straightforward equipment sensing where a 0.787" (20mm) target distance and a brass body matter more than compact mounting, but the electrical picture still stops short because the listing gives only the 10V to 30V supply range and 100Hz response frequency.
Use it only to keep an existing machine running. Betting a fresh design on a discontinued sensor with one unit on hand and unresolved compliance language is a bad trade.
The real constraint is availability, not sensing performance
Availability is the constraint. With stock quantity at 1, bulk packaging does not matter; E2E2-X20MD2 2M is a line-repair part, not a running production position.
View the Win-Source product page for E2E2-X20MD2 2M.
Would it fit the machine you already have?
Would it fit the machine you already have? Physically, maybe; electrically, only in part. The M30 threaded cylinder and cable-lead termination point to a panel or bracket mount with room for a large barrel sensor, and the supply rail must stay within 10V to 30V. The -25°C to 70°C operating temperature is a ceiling and floor, not a promise for every enclosure condition.
At 100Hz, E2E2-X20MD2 2M is not the choice for faster event detection where missed transitions become field faults, and the unshielded construction limits mounting freedom around nearby metal. IP67 helps in wet or dusty equipment, but it does not answer chemical exposure or cable-flex life.
What the listing still does not tell you
Wrong for a final release decision. The listing leaves out the details that close the review: no pinout detail beyond NC, 2-Wire, no mechanical drawing beyond M30 threaded cylinder, and no load or switching detail for the output.
Other gaps matter just as much. There is no current consumption, no output current limit, no sensing hysteresis, and no mounting-distance guidance for the unshielded body. For E2E2-X20MD2 2M, those omissions decide whether the PLC input behaves, whether the bracket clears surrounding metal, and whether the replacement drops into an existing harness without rework.
View the Win-Source product page for E2E2-X20MD2 2M.
Key Takeaways for Engineers & Buyers
- Freeze E2E2-X20MD2 2M out of new BOMs; lifecycle is Discontinued.
- Reserve the 1 unit only for an existing line stop or service need.
- Check panel space for the M30 threaded body and cable-lead exit before reuse.