12V ~ 24V, 20mm inductive sensing, M30 threaded body, -25°C ~ 70°C, IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Bulk |
| Core function | SENSOR PROX |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NC, 2-Wire; Response Frequency: 100Hz; Voltage - Supply: 12V ~ 24V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Can you still buy this for a running line?
Can I still get one for maintenance? Only if the line already depends on it. E2E2-X20MD2 5M is discontinued, and the lifecycle record points one way: one field says EOL and two say Discontinued. That settles the new-design question.
The supply problem is blunt. Stock is 1. With bulk packaging and cable leads, this is service stock at best, not something to count on for scheduled builds. Hold that single unit for failure recovery. EU RoHS is conflicted too, with one field compliant and another non-compliant, so regulated shipments need the manufacturer declaration checked first.
20mm is the fit call, not the whole fit story
20mm is the decisive number. It tells you where this sensor belongs, but not whether it drops cleanly into the machine, because the body is unshielded and the case is Cylinder, Threaded - M30.
That combination suits larger metalwork and machine frames better than tight brackets, where nearby steel can disturb the sensing field. The 12V ~ 24V supply range fits common industrial control rails. Interface fit comes down to the NC, 2-Wire output. Get that wrong, and the controller reads the wrong state even when the sensor is fine.
100Hz is enough for machinery, not for fast counting
100Hz is the ceiling here. Fine for presence detection and slower position checks; not for jobs where missed transitions become the failure mode.
The missing details are exactly the ones that close risk
And that is the real engineering gap. The listing gives the envelope, not the edge behavior. You have IP67, brass construction, cable leads, and an operating temperature range of -25°C ~ 70°C, so placement in a wet industrial environment is reasonable and the ambient upper limit is clear. That range is a limit, not proof of switching accuracy across the full span.
What is missing matters more than another line of catalog copy, because these are the details that decide whether a sustaining buy is safe to install on a live machine without surprises at startup or during fault tracing after a replacement. There is no pinout detail beyond Cable Leads, no mechanical drawing beyond M30 threaded cylinder, no load current figure for the 2-wire output, and no switching-point data such as hysteresis or repeat accuracy.
Those omissions drive the real risk. They determine whether the PLC input is compatible, whether the bracket clears the body, and whether the trip point stays where the machine needs it. There is also no indicator, so troubleshooting falls back to the controller side unless the full manufacturer documentation fills in the wiring and output behavior.
View the Win-Source product page for E2E2-X20MD2 5M.
Key Takeaways for Engineers & Buyers
- Stop new BOM releases on E2E2-X20MD2 5M; lifecycle is Discontinued.
- Check the control input against NC, 2-Wire behavior before touching a running line.
- Reserve the last 1 piece only for failure recovery on existing equipment.