Omron E2E2-X2B2-M1 discontinued for sustaining only

E2E2-X2B2-M1 Omron product image

10V ~ 55V supply, 2mm sensing, M12 threaded shielded body, -40°C ~ 85°C limits for existing fits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 55V
Reported stock0 pcs reported — confirm on RFQ

Wrong for new builds, still usable in a frozen machine

Wrong for new builds. E2E2-X2B2-M1 is already past the point where a new design-in makes sense: one field says EOL, Lifecycle Status says Discontinued, and Product Status says Discontinued. None of those signals support Active status, and stock is 0, so the lifecycle call is enough on its own before availability enters the picture.

It still has a narrow role in a frozen machine or existing production line that already expects a PNP-NC, 3-Wire inductive sensor with connector termination, a 0.079" (2mm) sensing distance, and a Cylinder, Threaded - M12 body, because those electrical and mechanical assumptions are usually expensive to unwind once the harness, bracketry, and PLC mapping are set. Bulk packaging doesn't change that. EU RoHS is compliant, but compliance does not offset end-of-life risk.

10V ~ 55V is the number that decides the control side

10V ~ 55V is the decisive figure on the control side. It places E2E2-X2B2-M1 across a wide range of industrial sensor rails, but it does not answer output current, voltage drop, or load compatibility, so it cannot settle the PLC input question by itself.

Two other numbers shape the fit: 0.079" (2mm) and 1.5kHz. The 2mm sensing distance is a hard limit, not extra margin, and poor bracket stack-up will show up as nuisance misses. The 1.5kHz response frequency matters for counting or position feedback, yet it remains only one timing figure. Without on/off delay detail, hysteresis, and target conditions, you cannot turn it into a full motion budget.

And the mechanical fit is just as narrow

And the mechanical fit is just as narrow. Shielded and M12 threaded points to a specific flush-style cylindrical inductive installation with connector access and only 2mm of required reach.

The real blocker is absence, not packaging

The constraint is absence: stock is 0 on a discontinued sensor. That makes this a line-support problem, not a future-build sourcing path.

The missing details that matter are concrete ones for interchange inside an existing machine: connector pinout, drawing detail beyond the M12 body callout, and switching behavior such as hysteresis or on/off delay. IP67, nickel-plated brass, and -40°C ~ 85°C set the environmental and body-style envelope, but they do not tell you whether the installed mating hardware, target geometry, or control input timing will match without rework. Freeze demand, then pull the full datasheet for service validation.

View the Win-Source product page for E2E2-X2B2-M1.

Key Takeaways for Engineers & Buyers

  • Block new BOM releases; E2E2-X2B2-M1 is discontinued and stock is 0.
  • Check controller input logic against PNP-NC, 3-Wire before touching harness or PLC mapping.
  • Confirm the machine really needs 1.5kHz response and 2mm sensing in an M12 shielded body.