20 VAC to 264 VAC, 2 mm shielded M12 inductive sensor, -40°C to 85°C, SCR-NO 2-wire output
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
| Reported stock | 0 pcs reported — confirm on RFQ |
Still, the stock position is the real brake
Still, Active status makes E2E2-X2Y1 fair game for new design-in, not just sustaining builds, and EU RoHS keeps compliance out of the way. The real brake is simpler: quantity is 0. If this sensor is already qualified in your machine, secure material against the build schedule; if it is not, don't plan a line around immediate availability.
This is a narrow-fit device anyway. It only makes sense when the application already wants an inductive, shielded, threaded M12 body with cable leads and a 2-wire SCR-NO output on an AC supply.
20 VAC to 264 VAC decides the control architecture
20 VAC to 264 VAC is the number that decides whether this sensor belongs in the panel at all. That range is the intended supply rail, and it quickly separates E2E2-X2Y1 from low-voltage DC sensing schemes before you even get to mounting, target material, or controller input details.
The 0.079" (2mm) sensing distance is just as defining. It suits close-in metal detection in a compact fixture, but it leaves little standoff margin, so a small error in target geometry or mounting stack-up turns into missed detection rather than a mysterious intermittent fault.
Output style matters too. SCR-NO, 2-Wire places E2E2-X2Y1 in AC-style sensing circuits and keeps wiring simple, but the listing still leaves the load-side behavior open. You'd want load current, off-state leakage, and voltage drop before closing out a clean PLC input design.
The 25Hz response frequency sets a ceiling. Fine for slow machine events, not fast indexing.
The environmental envelope is solid: -40°C to 85°C and IP67. Along with a nickel-plated brass body and threaded M12 cylinder, that points to a conventional hard-mounted industrial sensor position, not a lightweight bracket or embedded assembly.
The missing electrical detail is load behavior
The constraint is interface closure. This listing does not give load current, off-state leakage, voltage drop, pinout, or a mechanical drawing, and those are the details that finish the PLC input check and mounting release for E2E2-X2Y1.
Best in slow, close-in metal sensing on AC rails
The weak point comes first: E2E2-X2Y1 is wrong for long standoff detection, fast target counting, or low-voltage DC sensor buses. A 2mm sensing distance and 25Hz response frequency narrow the job quickly, while the AC supply range keeps it out of many DC-only control cabinets.
Where it fits is older or mixed-voltage industrial equipment that already uses AC-powered proximity sensing, wants a shielded flush-style installation, and has room for a threaded M12 body with cable leads. The LED indicator helps during setup, but the real fit is the combination of 20 VAC to 264 VAC, SCR-NO 2-wire output, and the short 2mm pickup window.
View the Win-Source product page for E2E2-X2Y1.
Key Takeaways for Engineers & Buyers
- Match the control rail first: E2E2-X2Y1 is listed only for 20 VAC to 264 VAC.
- Hold target spacing to the listed 0.079" (2mm); this is a short-range pickup.
- Book supply before release; quantity is 0 even though lifecycle is Active.