Omron E2E2-X2Y2 active for new design-in

E2E2-X2Y2 Omron product image

20 VAC to 264 VAC, 2 mm shielded inductive sensing, M12 threaded body, -40°C to 85°C

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC
Reported stock0 pcs reported — confirm on RFQ

2 mm is the decision-maker here

2 mm is the hard limit. E2E2-X2Y2 fits only where the target can be brought to 0.079" (2mm) repeatably; it is not the answer for wider mechanical tolerances, deep recesses, or moving metal that drifts in a loose bracket.

The rest of the package supports that narrow job. Shielded construction and a Cylinder, Threaded - M12 body point to flush mounting in metalwork, while cable leads and an LED suit machine frames and simple field wiring. This is a close-in industrial presence sensor, not a long-reach pickup.

The real constraint is speed and interface, not lifecycle

The real constraint is speed and interface. A 25Hz response frequency sets the ceiling for moving tooling or conveyor events, and that limit matters before lifecycle status does.

Output topology tightens the fit just as much. SCR-NO, 2-Wire points to an AC-style switching environment, and the listed 20 VAC to 264 VAC supply defines the allowed supply window. It does not say every load and control input will behave the same across that range, so compatibility still turns on the receiving circuit. If the input card expects a dry contact, transistor output, or DC sensor behavior, this listing does not close the match.

Environmental ratings help, but they don't save a bad interface choice. -40°C to 85°C covers cold starts and warm cabinets, and IP67 supports wet or dusty machine areas, yet neither one fixes a mismatch in switching speed or output type. Get those wrong and the field return won't be subtle.

Can you actually buy it for a build?

Can you buy it today? Not from the listed stock position: quantity is 0.

That does not push E2E2-X2Y2 into sustaining-only territory, because lifecycle is Active and the signals agree. It does change the buying move. Put it on a new BOM only if lead time can float, or reserve supply before the build is frozen. EU RoHS compliance is already in place, so availability is the blocker, not compliance paperwork.

Wrong for fast sensing, right for close-in machine detection

Wrong for fast counting or generous stand-off. Right for compact industrial detection where a metal target passes close to a flush-mounted body and the control side already expects a 2-wire SCR output.

The M12 threaded cylinder, nickel-plated brass body, and cable-lead termination fit straightforward machine mounting better than dense board-level assemblies or quick-swap connector schemes. E2E2-X2Y2 makes sense on guards, fixtures, and position checks where 25Hz is enough and 2mm is intentional.

What the listing still doesn’t answer

Missing details are concrete: pinout or lead wiring detail, a dimensional drawing beyond M12, and load-side switching details for the SCR-NO output. The listing also omits mounting-distance guidance beyond shielded construction.

View the Win-Source product page for E2E2-X2Y2.

Key Takeaways for Engineers & Buyers

  • Match the control circuit to SCR-NO, 2-wire output before releasing E2E2-X2Y2.
  • Hold mechanical stack-up to the 0.079" (2mm) sensing distance; this is a short-range sensor.
  • Cover the stock gap now: listed quantity is 0 even though E2E2-X2Y2 is Active.