Omron E2E2-X3D1 10M discontinued, sustaining use only

E2E2-X3D1 10M Omron product image

Stock 1, bulk package, discontinued status: this is a line-support question, not a fresh sensor choice.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors
PackageBulk
Core functionSENSOR PROX
Key electrical rangeNot listed for this part
Reported stock1 pcs reported — confirm on RFQ

1 piece changes the whole buying decision

1 unit is the entire listed stock. That alone is enough to rule out any program that expects continuity.

The lifecycle picture only tightens that conclusion. One field says EOL, two say Discontinued, and none say Active or NRND. There is no upside in that conflict. Use E2E2-X3D1 10M only to keep an existing production line moving for a specific need, and decide now what replaces it on the next build.

The constraint is missing electrical definition

The real constraint is missing electrical definition, not a tight voltage ceiling or a narrow temperature limit.

This listing identifies a proximity sensor in bulk packaging, but it does not state sensing distance, output type, supply voltage, response frequency, operating temperature, ingress rating, termination style, or housing. Those omissions decide whether the control input sees the right signal, whether the target can be detected at all, and whether the device survives the enclosure where it is mounted. Without those details, this page does not support a new design-in.

So fit is limited to exact known assemblies

So the fit narrows to assemblies that already call out E2E2-X3D1 10M and already have the mechanical and electrical behavior proven somewhere else.

Category alone tells you very little at integration time. A proximity sensor can miss on body size, cable exit, output wiring, or environmental sealing long before controller logic becomes the issue, and none of that is defined here. Bulk packaging also points away from automated intake and toward manual handling or service stock. Keep it in sustaining use where the installed base already defines the fit, and keep it out of new platforms where those missing sensor details would have to be rediscovered under schedule pressure.

Discontinued status, stock 1, and a RoHS conflict decide the action

1 unit is the decisive figure, because it turns a lifecycle warning into an immediate materials problem.

Discontinued already closes the door on new use, and the listed quantity removes any practical argument for stretching this part across forecast demand. Allocate that single piece only to an existing production shortage or a field return that cannot ship without the exact sensor. Then stop. The quantity does not support even a modest running line, and bulk packaging adds no supply advantage that changes the risk.

The compliance picture needs the same conservative treatment. One field says RoHS Compliant, while the specifications table says RoHS Non-Compliant. That's a hard conflict, not a wording quirk, and it matters anywhere EU RoHS requirements apply. Hold E2E2-X3D1 10M out of those builds until the manufacturer status is reconciled.

What the datasheet still has to answer

The listing is weak, but the conclusion is clear. The missing items that would close review are sensing distance, output type, supply voltage, and housing or pinout details.

View the Win-Source product page for E2E2-X3D1 10M.

Key Takeaways for Engineers & Buyers

  • Quarantine E2E2-X3D1 10M from new BOM releases; lifecycle is Discontinued.
  • Reserve the single listed unit only for an existing build stop or failure analysis need.
  • Block RoHS-controlled use until the RoHS Compliant versus RoHS Non-Compliant conflict is cleared.