10V to 30V supply, 2mm shielded M12 inductive sensor, -25°C to 70°C, IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
So the verdict is no new design-in
And that call is straightforward: E2E2-X3D1 is marked Discontinued, and the conflicting EOL signal only strengthens the case. This is a sustaining-only part. If you already ship it, secure the little stock that exists for existing production and move the assembly toward a qualified successor under your own process.
The buy-side constraint is immediate. Stock is 1, packaged in Bulk, so there is no realistic path here for a running line that needs continuity or controlled replenishment. EU RoHS compliance helps on materials policy, but it does nothing to change the lifecycle stop.
Wrong for long-reach sensing, right for tight metal detection
Not for stand-off sensing. The listed sensing distance is 0.079" (2mm), and that is the fit boundary that matters most in the machine. It belongs where the target can be brought very close and repeatably to the face, not in fixtures that need generous mechanical tolerance or a wider detection window.
A compact industrial mount is where it fits better: inductive, shielded, in a threaded M12 cylinder with cable leads and an LED indicator. The shielded construction points to flush-style mechanical integration, and the 1kHz response frequency is fast enough for ordinary position confirmation on moving hardware. In dense metalwork, the short range and package are the point.
The electrical numbers set interface limits, not comfort
The weak point comes first: the listing stops short of the load-side detail you would normally want. The useful part is that the few electrical limits it does give are enough to rule designs in or out quickly. Voltage supply is 10V to 30V. Treat that as the allowed rail window, not a promise that every control input and cable run will behave the same way across it.
Output type matters just as much: NPN-NO, 2-Wire. That settles the interface question for some PLC and input-card schemes and creates a problem for others, because a 2-wire sensor is not interchangeable with every 3-wire input expectation. Operating temperature is -25°C to 70°C, a listed limit that sets ambient fit but not self-heating margin. IP67 and a nickel-plated brass body point to wet, dirty industrial mounting, yet they do not answer chemical compatibility or washdown detail.
What the listing still doesn't tell you
The constraint is sign-off. You can decide lifecycle and broad fit from this listing, but not final electrical or mechanical acceptance.
Wiring detail is still thin. Beyond "Cable Leads," there is no pin-level or lead-level hookup information, so installation and controller connection remain unfinished. Mechanical definition is thin too: "Cylinder, Threaded - M12" tells you the format, but not thread length, body length, or sensing-face geometry, and those are the dimensions that decide bracket fit, target spacing, and service access once the machine is built.
The switching picture is also incomplete. You get 1kHz response frequency, but not the timing detail that often drives debounce settings and controller margin. There is no current consumption figure, no load current figure, and no leakage or voltage-drop detail for the 2-wire output. That gap matters because field trouble tends to show up right there, when an input card sits near its threshold instead of changing state cleanly.
Environmental fit still has open ends. IP67 is useful, and -25°C to 70°C sets the ambient ceiling and floor, but there is no cable specification, no bending detail, and no material compatibility note beyond nickel-plated brass. Those omissions matter more than any extra marketing language.
View the Win-Source product page for E2E2-X3D1.
Key Takeaways for Engineers & Buyers
- Block E2E2-X3D1 from new BOMs; lifecycle is Discontinued.
- Reserve the single available unit for failure analysis or line-down recovery.
- Check the control input against NPN-NO, 2-Wire and the 10V to 30V supply window.