10V ~ 30V, 3mm inductive NC 2-wire sensor in threaded M12 body, rated -25°C ~ 70°C
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Bulk |
| Core function | SENSOR PROX |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NC, 2-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Can you still buy this for a running line?
Can you still get it for a running line? Only for sustaining builds, and only when E2E2-X3D2 2M is already the qualified sensor. It is discontinued, stock is 0, and the EOL versus Discontinued conflict does not improve the supply outlook.
Wrong for new platforms, usable in sealed M12 fixtures
Wrong for any new platform. Discontinued status settles that before the electrical details matter.
It still fits existing inductive prox mounts built around a Cylinder, Threaded - M12 body, Cable Leads termination, and an NC, 2-Wire output. The 0.118" (3mm) sensing distance is a fixed mechanical constraint, not something you tune later, so a bracket or target stackup designed for more reach is already a mismatch. IP67 and a brass body suit dirty or wet machine areas, but they do not answer chemical exposure or washdown specifics.
10V ~ 30V and 1kHz decide the electrical fit
10V ~ 30V sets the supply ceiling and floor. That decides basic rail compatibility for E2E2-X3D2 2M, but it says nothing about noise margin, inrush, or output load behavior.
The NC, 2-Wire interface matters more if the control input expects a different wiring scheme. Then 1kHz becomes the next gate. It points to reasonably fast target detection, yet it still leaves pulse width, controller debounce, and edge behavior under marginal targets unresolved, and those gaps are exactly where intermittent detection shows up in the field instead of as a clean bench failure.
Temperature is bounded at -25°C ~ 70°C. It is an ambient limit, not an operating point to sit on while ignoring enclosure heating.
The real blocker is what the listing does not say
The weak point is documentation depth. The strong point is that the listed numbers are still enough to rule out bad fits quickly.
You do get the basics: category, body style, sensing distance, supply range, output type, temperature range, and ingress rating. That is enough to sort fixture fit and first-pass control compatibility. It is not enough to close a release, because the missing details are the ones that decide whether the sensor will behave in your exact machine once wiring, mounting tolerance, and input circuitry all meet each other at the same time.
There is no pinout detail beyond Cable Leads, no mechanical drawing beyond Cylinder, Threaded - M12, and no switching current or load specification for the NC, 2-Wire output. Those are decisive omissions. They determine controller interface, cable landing, and whether the sensor can actually drive the input circuit in front of it.
The listing also gives no guidance on hysteresis, repeatability, or target material dependence beyond calling the sensor inductive and shielded. On a 3mm device, those gaps surface quickly when a bracket shifts, a target finish changes, or a line gets rebuilt at another plant.
View the Win-Source product page for E2E2-X3D2 2M.
Key Takeaways for Engineers & Buyers
- Lock the NC, 2-Wire interface before touching the BOM; E2E2-X3D2 2M is not a drop-in choice by category alone.
- Check the machine envelope against the Cylinder, Threaded - M12 body and fixed 0.118" (3mm) sensing distance.
- Resolve the RoHS conflict before release; one field says RoHS Compliant and another says RoHS Non-Compliant.