Omron E2E2-X5B1-M1 discontinued, sustaining use only

E2E2-X5B1-M1 Omron product image

10V to 55V supply, 5mm shielded M18 inductive sensor, -40°C to 85°C, PNP-NO 3-wire

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 5MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 600Hz; Voltage - Supply: 10V ~ 55V
Reported stock0 pcs reported — confirm on RFQ

The real constraint is lifecycle, not sensing distance

Availability is the constraint here. Zero stock and a discontinued status answer the main question quickly: E2E2-X5B1-M1 is not a candidate for new design work. The lifecycle fields conflict between EOL and Discontinued, but neither reading supports Active or NRND, so the practical call stays the same.

For a running line, treat it as sustaining-only and secure any remaining qualified inventory path now. EU RoHS compliance is useful, but it does nothing to solve supply risk.

The 0.197" (5mm) sensing distance, M18 threaded body, and connector termination still matter because they describe the installed base this sensor fit. They do not change the sourcing reality. If E2E2-X5B1-M1 is already qualified in existing production, keep it there only long enough to cover a controlled migration. Otherwise, stop here.

The 10V to 55V rail is broad, but it is still a ceiling

Don’t design to the edge.

The listed 10V to 55V supply range is the electrical detail most likely to shape integration work on E2E2-X5B1-M1, because it spans a wide set of industrial DC rails without forcing an external interface just to satisfy supply voltage. Still, 55V is a ceiling. It is not an operating target for a noisy rail, especially when the listing does not include surge or protection detail.

The output format settles the next decision fast. PNP-NO, 3-wire belongs with sourcing inputs that expect a sourcing sensor, and it does not belong on an input card or harness laid out for NPN. Wire that mismatch into a machine and the failure mode is straightforward: the controller never sees the logic state it expects.

Speed is more nuanced. The 600Hz response frequency is enough to place this above slow presence sensing, and it supports fairly brisk target events, but it is still only one timing number. It does not tell you switching delay asymmetry, debounce behavior, or what happens near the 5mm limit when the target is marginal, misaligned, or moving through the edge of the sensing field.

The environmental numbers are solid boundary markers, not a full integration picture. A -40°C to 85°C operating range, IP67 ingress rating, and nickel-plated brass body fit dirty industrial mounting and washdown-adjacent areas, yet those facts still leave open the cable-side sealing details, connector orientation constraints, and the thermal margin left once the sensor sits inside a hot bracket or crowded enclosure.

Wrong for fresh platforms, still coherent in existing M18 builds

Wrong for fresh platforms that need a buyable sensor. Still coherent, narrowly, in existing machines already cut for a shielded M18 inductive body, wired for PNP-NO 3-wire output, and set around a 5mm trip point.

The missing details are the ones that close the review

Documentation depth is the weak point. The useful part is that the listing does pin down the basic fit: M18 threaded cylinder, connector termination, shielded inductive sensing, and a 600Hz response figure.

What is missing is concrete and important. There is no pinout, no mechanical drawing, no connector keying detail, and no switching-distance tolerance or hysteresis figure. For E2E2-X5B1-M1, those items decide bracket reuse, harness compatibility, and whether a nominal 5mm sensor trips where the machine expects it to.

The listing also omits load current and output protection behavior, so the input-loading question remains open from this page alone.

View the Win-Source product page for E2E2-X5B1-M1.

Key Takeaways for Engineers & Buyers

  • Block E2E2-X5B1-M1 from new BOMs; lifecycle is Discontinued and stock is 0.
  • Check the control input against PNP-NO, 3-wire output before touching harness or PLC wiring.
  • Hold the mechanical envelope to threaded M18 and the target gap to 0.197" (5mm).