10V to 55V supply, 5mm inductive range, M12 threaded body, -40°C to 85°C, IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 55V |
| Reported stock | 1 pcs reported — confirm on RFQ |
10V to 55V is broad, but it doesn't rescue the lifecycle
10V to 55V is a broad supply window. It makes E2E2-X5MB2-M1 easier to place on mixed industrial control rails, removing one common integration objection.
That still doesn't settle switching behavior, load compatibility, or cable-side protection, because the listing leaves wiring and output detail incomplete.
Lifecycle is the real stop. E2E2-X5MB2-M1 is marked Discontinued, with an EOL signal alongside it, so this is sustaining-only hardware even though the electrical range is appealing. EU RoHS compliance stays a positive, but it does not offset end-of-life risk.
Wrong for fresh platforms; still usable in sealed machine builds
Wrong for new programs. A discontinued inductive sensor with stock at 1 can stop a line long before anyone debates sensing distance.
E2E2-X5MB2-M1 still fits one narrow job: keeping an existing machine running when that machine already expects a PNP-NC, 3-Wire sensor in a Cylinder, Threaded - M12 body with Connector termination. Those details decide fit more than the category label does, because the output logic must match the input card, the thread must match the bracket, and the connector style must match the harness already in the cabinet. Miss any one of them and the part is not close enough.
The 0.197" (5mm) sensing distance is a maximum placement figure, not a guarantee that every target will switch cleanly at that gap in every installation. Add the Unshielded construction and the mounting becomes more specific: it belongs in a setup designed around its field shape, not in a crowded metal surround where someone assumes the M12 thread alone makes it interchangeable. IP67 and -40°C to 85°C support wet, dirty industrial service, but those are environmental ceilings, not proof that the mechanical envelope or target geometry will behave like the sensor already on the machine.
The 400Hz response frequency keeps it in ordinary position-detect duty. It still leaves timing margin unanswered because no switching waveform or load detail is listed.
Buy only to keep an existing line moving
Buy sparingly.
Stock is 1, and E2E2-X5MB2-M1 is discontinued.
That rules out any serious production commitment. If equipment is already qualified on E2E2-X5MB2-M1, reserve the remaining unit for a service event or a short sustaining run, then move the assembly onto an approved migration path instead of letting a single-sensor shortage drive downtime.
The missing details are the ones that close the real review
What does a buyer ask first? Will it wire in and mount without surprises?
This listing does not answer that fully. The pinout is absent, which matters for a PNP-NC, 3-Wire sensor with Connector termination. The mating connector details are absent too. There is no mechanical drawing beyond Cylinder, Threaded - M12, so thread length and body geometry remain unresolved. On the sensing side, there is no target specification or switching curve behind the 0.197" (5mm) figure, leaving that number useful for rough fit but not final placement.
View the Win-Source product page for E2E2-X5MB2-M1.
Key Takeaways for Engineers & Buyers
- Block E2E2-X5MB2-M1 from new BOMs; lifecycle is Discontinued and stock shows 1.
- Check the control input against PNP-NC, 3-Wire before touching harness or PLC wiring.
- Confirm the target and mount around the 0.197" (5mm) sensing distance and unshielded M12 body.