20 VAC ~ 264 VAC, 5mm inductive range, 25Hz response, M12 threaded body, -40°C ~ 85°C
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
| Reported stock | 1 pcs reported — confirm on RFQ |
Thin stock is the weak point; lifecycle is not
The weak point is inventory: stock shown is 1, so this is not a casual add to a fresh build without checking near-term demand. The stronger signal is lifecycle. It is listed Active in the lifecycle field, Active in Lifecycle Status, and Active again in Product Status, with no conflict called out.
That keeps Omron E2E2-X5MY1-M4 in play for new design-in when the machine already wants an inductive sensor with SCR-NO, 2-Wire output and a 20 VAC ~ 264 VAC supply range. EU RoHS is compliant. Use it for a running line or a controlled release, then secure the quantity you need before the BOM is frozen.
The real constraint is speed, not voltage
Speed is the first hard limit the numbers create. A 25Hz response frequency sets a ceiling on event rate, so Omron E2E2-X5MY1-M4 fits slower position detection and presence checks, not fast counting or tight timing where missed transitions turn into field faults.
The 0.197" (5mm) sensing distance is the next filter. You have the nominal reach, but not how much target material, mounting metal, or installation tolerance will reduce it. Because the sensor is unshielded, surrounding metalwork matters more to fit than the M12 threaded body alone suggests, and this listing does not include the mounting clearances that would settle that question.
Supply range matters in a different way. The listed 20 VAC ~ 264 VAC is a compatibility limit, not a promise that every point in that span behaves the same in leakage, turn-on, or load compatibility. Pair that with SCR-NO, 2-Wire output and the application is clearly AC machine I/O territory, where the wrong load can chatter, fail to release, or never register cleanly even though the supply number looked acceptable on paper.
Placement is easier to read. The -40°C ~ 85°C temperature range and IP67 rating support use on outdoor or washdown-adjacent industrial hardware more comfortably than many cabinet-only sensors, while the nickel-plated brass body and threaded M12 cylinder point to straightforward bracketed mounting rather than embedded placements.
5mm is enough only for close-in metal targets
5mm decides the job. Omron E2E2-X5MY1-M4 suits short-range metal presence on fixtures, stops, and actuator end positions. The connector termination helps serviceability, and the LED indicator helps commissioning.
What the listing still doesn't answer
What would stop a release first? The missing installation details. Omron E2E2-X5MY1-M4 is described as unshielded in a threaded M12 cylinder, but there is no pinout, no body drawing, and no mounting-clearance guidance, so the panel cutout and metal-surround rules are still open.
Electrical gaps remain. There is no load current figure, no off-state leakage, and no voltage drop for the SCR-NO, 2-Wire output. Those values decide whether a PLC input sees a clean state change or sits in the gray zone. For a sensor with a 25Hz response ceiling and a very broad 20 VAC ~ 264 VAC supply limit, those missing output details matter more than another line of description.
View the Win-Source product page for E2E2-X5MY1-M4.
Key Takeaways for Engineers & Buyers
- Match the control circuit to SCR-NO, 2-Wire output before releasing E2E2-X5MY1-M4.
- Keep targets inside the 0.197" (5mm) sensing distance ceiling for E2E2-X5MY1-M4.
- Cover immediate demand now; stock shown for E2E2-X5MY1-M4 is 1.