20 VAC to 264 VAC, 5 mm sensing, SCR-NC 2-wire output, M12 threaded body, -40°C to 85°C
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NC, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
| Reported stock | 1 pcs reported — confirm on RFQ |
Not for fast targets or low-voltage DC loops
Wrong for DC loops. Wrong for fast events.
The listed supply is 20 VAC to 264 VAC, and the response frequency is 25 Hz. That puts E2E2-X5MY2-M4 in straightforward AC presence sensing, not low-voltage DC inputs or quick edge capture.
20 VAC to 264 VAC decides the control architecture
20 VAC to 264 VAC is the figure that decides whether this sensor belongs in the schematic at all. It places the part on AC-powered sensing circuits, not the low-voltage DC prox input blocks many panels standardize on.
The output type matters just as much: SCR-NC, 2-Wire. That points to normally closed two-wire behavior, so the real decision is interface compatibility and fail-state philosophy as much as target detection at 0.197" (5mm). If that choice is wrong, the issue is not missed metal. It is a control input that behaves differently from the rest of the machine.
Good mechanical fit, but the sensing envelope is narrow
Mechanically, yes.
The package is familiar: Cylinder, Threaded - M12 with connector termination, a nickel-plated brass body, and IP67 ingress protection. That suits brackets, guards, and fixture stations where a threaded barrel sensor needs to live around washdown spray or coolant splash within an IP67-rated installation.
The sensing envelope is tighter. E2E2-X5MY2-M4 is inductive, unshielded, and listed for 0.197" (5mm) sensing distance. That 5 mm figure is the detection ceiling from this page; it does not settle side approach behavior, target material effects, or flush-mount assumptions. Unshielded construction also affects how closely metal can crowd the barrel, and the needed mounting clearances are not listed here.
25Hz is the throughput limit, and the datasheet gaps matter
25 Hz sets the pace, and it can rule the part out before anything else does. For a simple end-of-travel check or part-present station, that may be enough. For a conveyor count point, cam replacement, or any sequence where targets arrive quickly and the PLC logic expects crisp state changes, 25 Hz is the first number that can disqualify E2E2-X5MY2-M4 even when the 5 mm sensing distance, M12 body, and AC supply range all line up neatly with the mechanical concept.
The temperature range is broad: -40°C to 85°C. Treat that as the ambient operating ceiling and floor, not proof of extra thermal margin inside a sealed enclosure or beside a hot motor. The LED indicator will help during commissioning and fault finding, but it does not answer the harder integration questions.
Those gaps are concrete. The connector pinout is not stated. A mechanical drawing for mounting and keep-out is not stated. Switching detail beyond the single 25 Hz figure is not stated. E2E2-X5MY2-M4 may still be the right sensor, but those are the omissions that slow integration and force extra checking at the panel and bracket level.
Can you actually build with it now?
Can you get enough parts?
Stock is listed at 1, and that is the immediate constraint. Lifecycle is Active and EU RoHS compliance is listed, but a quantity of 1 makes this a weak choice for an immediate production release unless supply is already secured.
Use E2E2-X5MY2-M4 for qualification or a controlled build, then lock the production quantity before freezing the line.
View the Win-Source product page for E2E2-X5MY2-M4.
Key Takeaways for Engineers & Buyers
- Match the input rail to 20 VAC to 264 VAC before releasing E2E2-X5MY2-M4 on the BOM.
- Keep E2E2-X5MY2-M4 out of fast count points; the listed response frequency is 25 Hz.
- Do not start a build on listed stock of 1; lock supply before committing E2E2-X5MY2-M4.