20 VAC to 264 VAC, 5mm shielded inductive sensing, M18 threaded body, -40°C to 85°C
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NO, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
| Reported stock | 1 pcs reported — confirm on RFQ |
20 VAC to 264 VAC is the number that decides this part
20 VAC to 264 VAC sets the boundary. It tells you right away that E2E2-X5Y1-US belongs in direct AC presence sensing inside industrial cabinets, not in the low-voltage DC sensor jobs that dominate newer machine builds, and that single range does more to define fit than any marketing label ever could.
Pair that supply range with SCR-NO, 2-wire output and the application narrows fast. This part fits simple series-wired detection circuits where AC compatibility matters more than fast switching or logic-level interfacing.
The 0.197" (5mm) sensing distance is the next hard limit. It settles reach. It does not settle target tolerance or mounting offset. With shielded construction in a threaded M18 cylinder, E2E2-X5Y1-US makes sense where you need a flush-style metal-barrel install and can bring the target into that 5mm window. Miss the geometry and the rest of the spec sheet stops mattering.
Then there is 25Hz. Treat it as a response-frequency ceiling, not an operating point to lean on casually. It works for slow machine states, gate positions, and presence checks, but it rules out applications where event rates are high enough that missed transitions turn into a field problem instead of a bench note.
Wrong for PLC logic inputs, right for AC machine sensing
Wrong for a low-voltage PLC input card expecting a DC transistor output. E2E2-X5Y1-US is an inductive, SCR-NO, 2-wire device with a 20 VAC to 264 VAC supply range, so it belongs in older or AC-native control schemes where the load path and sensor type were chosen around AC switching from the start.
Where it does fit is straightforward industrial metal detection with modest speed and harsh-environment exposure. IP67 and NEMA 1,4,6,12,13 support washdown and enclosure-side use, while the nickel-plated brass body and cable leads suit machine-mounted installs better than panel-only hardware. The -40°C to 85°C operating temperature range is broad enough that ambient is unlikely to be the first rejection point, but it still leaves cable flex life, chemical resistance, and mounting clearances unanswered.
Buy it for a running line only after supply is real
Supply is the issue.
Lifecycle is clean: Active across the listed signals, with no conflict, and EU RoHS is straightforward. Inventory is the constraint, not status. With stock quantity 1, E2E2-X5Y1-US can be approved technically, but it should not be released into a build until actual supply is secured against the demand window.
The missing details are the ones that close the install
The weak point is documentation depth. What is missing matters: no pinout or wiring detail beyond cable leads and SCR-NO, 2-wire, no mechanical drawing beyond M18 threaded cylinder, no switching current data, and no load-side electrical limits showing what E2E2-X5Y1-US can drive in the field.
View the Win-Source product page for E2E2-X5Y1-US.
Key Takeaways for Engineers & Buyers
- Match the input circuit to SCR-NO, 2-wire operation on 20 VAC to 264 VAC.
- Hold the target inside the 0.197" (5mm) sensing limit; shielded construction won't forgive extra gap.
- Do not release E2E2-X5Y1-US to production on stock quantity 1; secure the line item first.