20 VAC ~ 264 VAC, 5 mm inductive range, M18 threaded body, -40°C ~ 85°C, SCR-NC 2-wire output
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 85°C; Output Type: SCR-NC, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC |
| Reported stock | 1 pcs reported — confirm on RFQ |
The stock is thin, but the part itself is designable
The weak point comes first: stock is 1. The stronger point is that E2E2-X5Y2-M4 carries no lifecycle warning, and the listed electrical and mechanical identity is specific enough to support a real design-in decision rather than a placeholder match.
What makes that possible is the combination of 20 VAC ~ 264 VAC supply, SCR-NC, 2-Wire output, and a Cylinder, Threaded - M18 body. This is not a generic low-voltage DC prox you can drop anywhere; it belongs in industrial AC sensing circuits that already expect a 2-wire normally closed SCR output and have room for an M18 threaded barrel, while the 0.197" (5mm) sensing distance sets a hard placement ceiling because no adjustment detail is shown.
Operating Temperature of -40°C ~ 85°C and IP67 help define plant-floor fit, but they do not answer washdown chemistry, cable routing, or mounting heat. EU RoHS is present. Put plainly, E2E2-X5Y2-M4 is suitable for new design-in when the interface already matches, and for sustaining lines once supply coverage is in place.
The 25Hz response is the first no-go check
Start there.
A 25Hz response frequency rules out fast counting and tight pitch detection. E2E2-X5Y2-M4 fits presence sensing, position confirmation, and slower machine states.
Can you actually buy it for a build?
Can you get enough of it? Yes, but not casually. The lifecycle status is Active, yet the listed quantity is 1, so the immediate risk is availability, not product status.
Use E2E2-X5Y2-M4 for qualification or a controlled service need, not as an unchecked release for a fresh production run. Bulk packaging is fine for bench and panel builds, but it gives no help on feeder assumptions or kitting density.
5 mm and M18 tell you where this sensor belongs
0.197" (5mm) is a short sensing ceiling. That matters because the M18 threaded body points to a rigid bracket, a known target path, and machine geometry that can hold the gap consistently instead of asking the sensor to cover loose mechanics.
The shielded construction helps when the mounting face sits close to surrounding metal, while nickel-plated brass and IP67 point to ordinary industrial exposure rather than a fragile enclosure-mounted device. The fit is straightforward: conveyor presence checks, end-of-travel confirmation, and station interlocks on AC-powered control hardware. If the machine uses low-voltage DC sensor buses, needs normally open logic, or depends on long standoff distance, E2E2-X5Y2-M4 is the wrong starting point.
What the listing still doesn’t answer
And this is where the page stops. The connector is named only as Connector, so the mating style and pinout are still open questions. The listing also does not show a drawing, switching current detail, or load limits for the SCR-NC, 2-wire output.
Those gaps matter more than extra copy. Without the pinout and connector definition, harness release is blocked; without the drawing, bracket and panel clearances stay provisional; without output load detail, input compatibility remains an assumption.
View the Win-Source product page for E2E2-X5Y2-M4.
Key Takeaways for Engineers & Buyers
- Match the input stage to SCR-NC, 2-wire behavior before assigning E2E2-X5Y2-M4 to a PLC channel.
- Hold the mechanical envelope to Cylinder, Threaded - M18 and the sensing target inside 0.197" (5mm).
- Do not release E2E2-X5Y2-M4 to production on a stock position of 1; place coverage first.