Omron E2E2-X5Y2-US 5M is active but stock is thin

E2E2-X5Y2-US 5M Omron product image

20 VAC to 264 VAC, 5 mm sensing, SCR-NC 2-wire output, M18 threaded body, -40°C to 85°C

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 5MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: SCR-NC, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC
Reported stock1 pcs reported — confirm on RFQ

Active part, narrow buying window

Good for design-in.

Lifecycle status is Active with no conflict in the listing, so the part itself is not the reason to avoid a new program. The reason to pause is supply: stock is 1. That is enough for evaluation, not enough to support a fresh build without securing more supply. EU RoHS is listed, which clears a routine compliance check.

The real constraint is speed, not sensing distance

Speed is the limit here. A 25 Hz response frequency puts this sensor in slow machine-state detection, part presence, and end-of-travel jobs, not in fast counting or tightly timed position confirmation where missed transitions turn into field faults.

The 0.197" (5mm) sensing distance answers a different question: how close the target must come before detection. It does not answer tolerance to target material changes, mounting metal around the face, or switching repeatability. Shielded construction helps when the sensor has to live near surrounding metal, and the M18 threaded cylinder points to a standard barrel-mount industrial package rather than a miniature head for cramped tooling.

AC supply range decides the control architecture

And that matters only if the control side matches. The listed 20 VAC to 264 VAC supply range is the operating window for an AC-powered sensor, and it decides whether E2E2-X5Y2-US 5M belongs in the panel at all. It fits AC control voltages across a wide span, but not low-voltage DC input cards or transistor-style sensor interfaces.

The SCR-NC, 2-wire output is just as important. This is not a generic dry contact and not a 3-wire DC output you can drop into any PLC input drawing. Get that wrong and the channel may never release cleanly, never register, or behave differently from the rest of the machine because the input circuit was chosen for another output style.

5 mm reach is only half the fit decision

5 mm is enough for ordinary metal-target detection on guards, actuators, and machine stations where the target can be brought close and the event rate stays modest.

The -40°C to 85°C operating temperature and IP67 with NEMA 1,4,6,12,13 make the mechanical case stronger than the electrical listing alone. This sensor is built for plant-floor exposure, washdown splash, and temperature swings that would rule out lighter-duty housings, and that matters more in practice than a broad supply range if the installation lives in a dirty enclosure, on a wet machine, or near seasonal temperature extremes.

The nickel-plated brass body and cable-lead termination push the fit in a familiar direction. You are designing around a threaded barrel sensor that mounts through a bracket and leaves on a fixed cable, not a quick-disconnect body meant for frequent field replacement. That's fine for sealed equipment, but it is the wrong choice where maintenance policy expects connectorized swap-out.

This is also where the listing stops being enough. E2E2-X5Y2-US 5M gives no pinout detail beyond cable leads, no body drawing, and no mounting dimensions beyond M18 and cylindrical form. Those omissions decide bracket clearance, cable exit routing, and whether the sensor can physically replace what is already on the machine.

Buy it for a specific AC sensing job, not as a general spare.

What the listing still doesn’t answer

20 VAC to 264 VAC is the key figure, but not the last one needed. Missing details are the cable-lead wiring, the M18 mechanical drawing, the SCR-NC load-side switching details, and any stated repeat accuracy or hysteresis data.

View the Win-Source product page for E2E2-X5Y2-US 5M.

Key Takeaways for Engineers & Buyers

  • Match the input circuit to SCR-NC, 2-wire switching before assigning E2E2-X5Y2-US 5M to a PLC or relay load.
  • Keep E2E2-X5Y2-US 5M in applications that only need 25 Hz response; faster target events belong elsewhere.
  • Do not release a build on stock quantity 1; lock supply before adding E2E2-X5Y2-US 5M to a running BOM.