Omron E2E2-X5Y2 active inductive sensor for new design-in

E2E2-X5Y2 Omron product image

20 VAC to 264 VAC, 5 mm range, SCR-NC 2-wire output, M18 threaded body, -40°C to 85°C

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 5MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: SCR-NC, 2-Wire; Response Frequency: 25Hz; Voltage - Supply: 20 VAC ~ 264 VAC
Reported stock0 pcs reported — confirm on RFQ

20 VAC to 264 VAC decides the interface, not the mount

20 VAC to 264 VAC is the number that decides whether this sensor fits the design at all. Before the M18 barrel, before the 5 mm sensing distance, and before any mounting bracket discussion, the real question is whether the receiving side is built for an SCR-NC, 2-wire output on an AC line.

The 0.197" (5mm) sensing distance answers only one thing: how close the target must get. It does not answer target material tolerance, switching hysteresis, or how much margin remains once the sensor sits inside a bracket or metalwork. The 25Hz response frequency is also a ceiling, not a working assumption, and that one number sharply limits where E2E2-X5Y2 belongs. It fits slow machine-state detection and straightforward presence checks, but it is out of place where targets move fast enough that missed transitions turn into a field issue.

Environmental limits are solid. E2E2-X5Y2 carries -40°C to 85°C operating temperature and IP67 ingress protection, so it can be placed in outdoor-adjacent industrial hardware or washdown-prone equipment. Still, those are environmental boundaries, not evidence that the electrical side will tolerate a noisy control cabinet without the right interface around it.

Buy it for new work, but not from empty stock

Active is clear.

E2E2-X5Y2 is a valid new design-in candidate on lifecycle alone, with EU RoHS listed and no lifecycle conflict, but stock is 0. Treat sourcing as the gating action and place it only where the schedule can absorb lead time.

The fit is narrow: AC machine sensing, not fast feedback

The constraint is speed plus interface. An AC supply, a normally closed SCR output, and a 25Hz response ceiling narrow E2E2-X5Y2 to industrial presence sensing where cable leads are acceptable in the harness.

The shielded construction and threaded M18 cylinder point to flush or bracketed mounting in metalwork, where the package matters as much as the sensing face. It does not belong in high-speed counting, tight timing loops, or control schemes that expect a DC transistor-style output. That's not a flaw. It is the application boundary.

What the listing still doesn't answer

And those boundaries are exactly why the missing details matter. E2E2-X5Y2 still lacks pinout or wiring detail beyond cable leads, so the lead assignment is still needed before the harness is committed. The drawing is absent as well, leaving thread length, body length, and sensing-face geometry unresolved even with M18 already stated.

The electrical gaps are just as practical. There is no load current figure, no leakage or voltage drop detail for the SCR-NC output, and no switching differential or repeat accuracy. Those omissions decide PLC input compatibility and detection margin far more directly than the LED indicator does.

View the Win-Source product page for E2E2-X5Y2.

Key Takeaways for Engineers & Buyers

  • Match the input circuit to SCR-NC, 2-wire operation before releasing E2E2-X5Y2.
  • Hold the mechanical envelope to the threaded M18 body and 5 mm sensing distance.
  • Plan sourcing early; stock is 0 even though E2E2-X5Y2 is Active.