Omron E2E2-X7D1 10M discontinued, sustaining use only

E2E2-X7D1 10M Omron product image

Discontinued status, 1 unit listed, Bulk package: supply decides this part before the sensor specs do.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors
PackageBulk
Core functionSENSOR PROX
Key electrical rangeNot listed for this part
Reported stock1 pcs reported — confirm on RFQ

Then the lifecycle call is easy

And that is enough to rule E2E2-X7D1 10M out of any new build. The lifecycle record says Discontinued, while another signal says EOL; that conflict does not create upside, and it confirms the part is already outside a safe new-design window.

For a running line, E2E2-X7D1 10M is a containment exercise, not a fresh design choice. Keep the remaining material for existing production, and note the EU RoHS versus RoHS Non-Compliant conflict on the part record because compliance is not cleanly settled here.

A poor fit for any fresh sensor release

Wrong for a new platform. E2E2-X7D1 10M is discontinued, listed in Bulk, and shows 1 unit. It fits only a sustaining build that needs this exact sensor and can consume loose stock without expecting a running line.

The real problem is what the listing does not say

Not enough here.

E2E2-X7D1 10M sits in Proximity Sensors, but the electrical and mechanical numbers that decide whether it can actually replace itself on a machine are absent here: no sensing distance, no supply voltage, no output type, no response frequency, no operating temperature, no ingress rating, and no termination style.

That missing set matters more than the category label because each field closes a different failure mode, and without sensing distance you cannot tell whether the target will be seen at the installed gap, while without output type or supply voltage you cannot tell whether the input card will read it safely, and without operating temperature or ingress protection you cannot tell whether the field environment will age it out early or reject it at incoming inspection.

The package line says Bulk, and that only tells you how it ships, not how it mounts. E2E2-X7D1 10M may still be the right sustaining part if the installed base already proves the fit, but this page cannot support a new mechanical or electrical release on its own.

1 unit is the only number that closes a decision

1 unit. That figure settles the buy call faster than anything else on the page. One unit listed means E2E2-X7D1 10M is not something you schedule against for production continuity; reserve it only if a stopped line needs this exact part now.

The other listed quantity is 0, so availability is plainly unstable. Pair that with the discontinued status and treat E2E2-X7D1 10M as a last-piece recovery buy, not a replenishment source.

View the Win-Source product page for E2E2-X7D1 10M.

Key Takeaways for Engineers & Buyers

  • Stop new BOM releases on E2E2-X7D1 10M.
  • Quarantine the 1 listed unit for existing production only.
  • Resolve the RoHS Compliant versus RoHS Non-Compliant conflict before shipment.