10V ~ 30V, 8mm inductive NC 2-wire sensor in a cylinder body, rated -25°C ~ 70°C and IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors |
| Package | Bulk |
| Core function | SENSOR PROX |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NC, 2-Wire; Response Frequency: 800Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Can you still buy this for a running line?
Can you still keep a line running with it? Only barely. The lifecycle status is Discontinued, and the notes also show an EOL signal, so no conservative reading supports new design use.
For an existing machine build or service line, availability is the immediate problem. Stock is 1 and packaging is Bulk. Take the last piece only if it closes a short-term gap, then move the line to an approved successor through your own change process. EU RoHS status is conflicted too, with one field marked compliant and another non-compliant, so keep E2E2-X8MD2 2M out of any build that needs a clean compliance file.
The real constraint is fit, not frequency
The hard constraint is interface fit. The 10V ~ 30V supply range places this sensor on industrial DC rails inside that window, but it says nothing about current draw, voltage drop, or how much margin is left at the low end of the loop.
The NC, 2-Wire output is the bigger retrofit issue than the 800Hz response, because a two-wire normally-closed sensor can create compatibility problems with the input card and load that a three-wire device would avoid. That question lands before speed in most replacements.
The 0.315" (8mm) sensing distance is the other fixed boundary. It sets bracket geometry, target approach, and whether the existing mechanical stack-up can stay as-is; it does not promise stable detection across every target material or mounting condition. Since the body is unshielded and cylindrical, flush-mount assumptions are unsafe unless the manufacturer drawing says so.
IP67, brass construction, and -25°C ~ 70°C describe ordinary machine-side hardware, but they are still limits and enclosure facts, not proof of survival in washdown chemistry, hot cabinets, or operation at the edge of the temperature range.
800Hz is enough, but it is not the buying problem
800Hz is the listed response ceiling. That is enough to matter for faster position sensing, but it is not why this part falls out of consideration; lifecycle status and stock are the real blockers.
The missing details are the ones that close the review
Some key details are missing.
There is no pinout beyond Wire Leads, no mechanical drawing beyond Cylinder, and no current or load specification to show how the 2-wire NC output behaves on the input it must drive.
The listing also omits the target conditions behind the 0.315" (8mm) claim and gives no mounting detail for the unshielded body. Those gaps decide whether E2E2-X8MD2 2M drops into an existing bracket cleanly or becomes a field-fit problem.
View the Win-Source product page for E2E2-X8MD2 2M.
Key Takeaways for Engineers & Buyers
- Freeze E2E2-X8MD2 2M to existing production only; lifecycle is Discontinued and stock is 1.
- Check the loop against 10V ~ 30V and NC, 2-Wire behavior before touching the BOM.
- Resolve the RoHS conflict now; one field says compliant and another says non-compliant.