10V to 30V supply, 12mm sensing, M30 threaded body, -10°C to 70°C, IP67 — but lifecycle stops new use
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIV 12MM CYL 2M |
| Key electrical range | Operating Temperature: -10°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 50Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Can you still design this in?
For new work, no. E2EF-QX12D1 2M should be treated as EOL because both the lifecycle field and Lifecycle Status say EOL, even though Product Status says Active. That conflict does not reopen it for fresh designs; it shows the records are out of step.
For an existing production line, E2EF-QX12D1 2M is a sustaining buy at best. EU RoHS is not cleanly settled here either, because one compliance field says compliant while another says non-compliant, so don’t let this part through a compliance gate on this page alone.
50Hz is the number that decides machine speed
50Hz is the ceiling that decides whether this sensor fits the job. It puts E2EF-QX12D1 2M on slower presence detection and position confirmation, not on fast counting or short dwell detection where missed transitions turn into intermittent field faults that are hard to reproduce once the machine is back in service.
The 10V ~ 30V supply range is also a limit, not a promise that every control rail inside that span behaves the same way in your cabinet. It answers one question cleanly: the sensor can live only on systems that stay within 10V and 30V. Startup behavior, brownout behavior, and output loading remain open because no current draw, voltage drop, or switching detail is listed here.
The sensing envelope is just as restrictive. A 0.472" (12mm) sensing distance with shielded construction points to controlled, close-in metal target detection rather than generous stand-off. Get that wrong and setup margin disappears first; then nuisance misses show up as the machine warms, vibrates, or drifts in fixture position.
Temperature and ingress ratings still matter, but they are ceilings too. The -10°C ~ 70°C operating temperature and IP67 rating say E2EF-QX12D1 2M can tolerate ordinary industrial washdown and moderate ambient exposure. They do not answer cable flex life, chemical compatibility, or what thermal margin remains once the sensor is buried in a hot enclosure.
The package locks this into a specific kind of install
The constraint is physical before it is electrical. A Cylinder, Threaded - M30 body in stainless steel with cable leads is a machine-mounted sensor format, not a compact electronics assembly choice, and E2EF-QX12D1 2M needs the panel real estate and bracket geometry that come with that diameter.
Use it where a 12mm inductive trip point, a visible LED indicator, and IP67 sealing matter more than miniaturization. Skip it where tight sensor spacing, quick field replacement with a connector, or high-speed detection are the real job, because the M30 body, 2-wire NPN-NO output style, and 50Hz response ceiling push the fit the other way.
What the listing still doesn't answer
Not enough yet.
The missing items that would actually close a review are the pinout or wiring detail for the 2-wire NPN-NO output, the body drawing beyond the M30 callout, and the load or output-current limits. The listing also does not give switching hysteresis or repeat accuracy, and those numbers decide whether E2EF-QX12D1 2M will hold a stable trip point in a real fixture.
View the Win-Source product page for E2EF-QX12D1 2M.
Key Takeaways for Engineers & Buyers
- Block new BOM releases on E2EF-QX12D1 2M; lifecycle is EOL despite an Active product-status flag.
- Check the machine cycle against 50Hz before reuse; that ceiling can miss fast target events.
- Confirm panel space for the M30 threaded body and cable-lead exit before committing harness layout.