2mm sensing, 10V ~ 30V supply, M8 threaded body, -10°C ~ 70°C operation, 200Hz response
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 2MM CYL 2M |
| Key electrical range | Operating Temperature: -10°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 200Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
2mm is the number that decides this sensor
0.079" (2mm) is the design-in gate for E2EF-QX2D1 2M. If the target cannot be held that close, the rest of the spec barely matters.
That small sensing distance puts the part in tight metal-detection geometry, where target position is controlled and repeatable. The body is a threaded M8 cylinder, the sensor is shielded, and the housing is stainless steel, so it reads as a compact flush-mount inductive pickup for cramped fixtures and guarded machine positions rather than a general-purpose long-range prox. IP67 helps in washdown or splash zones, but it does not fix a layout that cannot keep the target inside 2mm.
Active status is fine; availability is not
Buy carefully.
The lifecycle call is clear: Active, with matching lifecycle signals and no stated conflict, so E2EF-QX2D1 2M is a valid candidate for new work and existing production. Availability is the real problem. Quantity is 1, and that is too thin for pilot builds, service spares, and line continuity at the same time.
The electrical envelope narrows the use case further. A 10V ~ 30V supply range fits common industrial DC rails, but the record still leaves out input current, load current, and ON-state voltage drop. Those gaps matter with an NPN-NO, 2-Wire output, because interface mistakes here turn into false state detection or a sensor that never releases cleanly. The 200Hz response frequency is also a ceiling, not a typical point, so it suits moderate machine events and not fast tooth counting or very short target dwell where missed transitions become a field problem.
The compliance issue is just as direct. One field says RoHS Compliant and another says RoHS Non-Compliant. Keep E2EF-QX2D1 2M out of compliance-sensitive builds until Omron resolves that conflict; EU RoHS cannot be assumed from contradictory records.
View the Win-Source product page for E2EF-QX2D1 2M.
The weak point is missing interface detail
The weak point comes first: documentation depth is thin. What is missing is load current, residual voltage for the 2-wire output, pin or lead assignment, and a mechanical drawing beyond “Cylinder, Threaded - M8.”
200Hz sets the speed ceiling
200Hz is the only explicit dynamic limit here, so it carries more weight than the rest of the motion story.
It supports ordinary position confirmation, part presence, and end-of-stroke detection, but it leaves little room for high-rate event capture where target size, gap, and dwell time start interacting. The listed operating range is -10°C ~ 70°C, a ceiling for ambient use rather than a promise about self-heating or enclosure rise, and IP67 supports wet industrial placement. Put it in compact machinery and guarded tooling where the target comes close, the rail stays within 10V ~ 30V, and the cycle speed remains inside what 200Hz can support.
View the Win-Source product page for E2EF-QX2D1 2M.
Key Takeaways for Engineers & Buyers
- Lock the machine geometry around the 0.079" (2mm) sensing distance; this part gives little standoff.
- Match the control input to NPN-NO, 2-Wire before release; that output choice decides wiring compatibility.
- Stop compliance release until the RoHS conflict is cleared, and secure stock early because quantity is 1.