Omron E2EF-QX3D1 2M: sustaining only, not new design-in

E2EF-QX3D1 2M Omron product image

10V to 30V supply, 3mm sensing, M12 threaded body, -10°C to 70°C limits its fit

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 3MM CYL 2M
Key electrical rangeOperating Temperature: -10°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 80Hz; Voltage - Supply: 10V ~ 30V
Reported stock0 pcs reported — confirm on RFQ

Wrong for new builds, acceptable only in a running line

Wrong for a new platform. The lifecycle call is EOL, and that outweighs the conflicting Active product-status field when you are deciding whether to release fresh drawings or a new BOM.

It still fits existing production that already uses a shielded inductive sensor with 0.118" (3mm) sensing distance, an M12 threaded cylinder, and cable leads. That is a narrow fit, not a general-purpose one. Inventory is 0, and the RoHS fields conflict, so this stays a sustaining part until those two commercial facts are cleared.

The weak point is availability, not the package

Availability is the problem. Zero on hand is the immediate constraint, while Bulk packaging changes nothing; if this sensor is on a live line, reserve stock from approved channels now and keep it tied to existing assemblies only.

View the Win-Source product page for E2EF-QX3D1 2M.

The 3mm reach and 80Hz response define the real fit

And that is where the fit gets tight. The 0.118" (3mm) sensing distance is the first hard boundary on fixture design, target placement, and tolerance stack, so if the machine needs more stand-off, this part is out before wiring even starts.

The 80Hz response frequency sets the next ceiling. It belongs on slower position confirmation and presence detection, not fast counting jobs where missed transitions turn into intermittent field faults that are hard to reproduce. The 10V ~ 30V supply range covers common control rails, but it does not answer interface behavior on its own; the listed output is NPN-NO, 2-Wire, and that has to match the input card already in the design.

Mechanical fit is just as specific. The body is stainless steel, shielded, and built as a Cylinder, Threaded - M12 with IP67 protection, so it suits washdown-adjacent industrial mounting better than open-board sensing. IP67 is an ingress ceiling, not a statement about every chemical, connector treatment, or cable bend condition in the machine.

10V to 30V is useful, but not enough detail is published

10V ~ 30V gives the supply window, not the load behavior. The missing items are concrete: output current, voltage drop in the 2-wire output path, pinout or lead assignment, and a dimensional drawing beyond the M12 threaded body callout. Without them, you cannot finish input loading, harness mapping, or bracket clearance with confidence.

The listing also omits switching waveform detail beyond 80Hz. That leaves no published timing granularity for edge behavior, and no drawing to settle the exact installed envelope.

View the Win-Source product page for E2EF-QX3D1 2M.

Key Takeaways for Engineers & Buyers

  • Block new releases on E2EF-QX3D1 2M; lifecycle is EOL despite an Active product-status field.
  • Match the control input to NPN-NO, 2-Wire before touching the harness or PLC card.
  • Keep E2EF-QX3D1 2M in wet machinery only if IP67 and the 2M cable length already fit the build.