10V ~ 30V supply ceiling, 7mm sensing, M18 threaded body, -10°C ~ 70°C, 100Hz response
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 7MM CYL 2M |
| Key electrical range | Operating Temperature: -10°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Still usable in a running line, but stop designing it in
And that lifecycle conflict is the whole story here: E2EF-QX7D1 2M is not a safe new-design choice. Two lifecycle fields call it EOL, one product-status field says Active, and the conservative reading wins because a line stop caused by an unavailable sensor is harder to absorb than a planned redesign.
For sustaining builds, it can still fit if the machine already expects an inductive, shielded, M18 cylindrical sensor with cable leads and an NPN-NO, 2-Wire output. Inventory is 0, so this is not a part to leave on open demand. RoHS status also conflicts, with one field compliant and another non-compliant, so compliance is not settled.
The electrical limits narrow the fit fast
The weak point is speed. The strong point is that the rest of the envelope is familiar industrial territory: a 10V ~ 30V supply range, 0.276" (7mm) sensing distance, and -10°C ~ 70°C operating temperature.
Those numbers answer different questions. The 10V ~ 30V supply range sets the supply ceiling and floor, but it does not answer noise margin, surge tolerance, or output loading. The 0.276" (7mm) sensing distance sets fixture geometry and target approach, not guaranteed detection through every mounting stack-up, and the -10°C ~ 70°C operating temperature closes the ambient question for ordinary indoor equipment but not washdown heat, enclosure rise, or cold-start behavior outside that range. Get any of those wrong and the result is predictable: missed targets, wiring mismatches, or a sensor with no environmental headroom left.
This belongs on slower industrial sensing jobs
Use it there.
The mechanical package does real work here. It is an inductive proximity sensor in a threaded M18 cylinder with a stainless steel body, shielded construction, IP67 ingress protection, LED indication, and cable leads, so it fits straightforward metal-target detection on machinery where a threaded barrel mount and fixed lead exit are already part of the build.
It does not belong in applications that need compact board-level integration, connectorized field replacement, or fast event capture. The 100Hz response frequency is the first limiter, and the NPN-NO, 2-Wire output is the second because it has to match the input expectations of the receiving control hardware rather than being treated as a generic sensor output.
7mm is not enough information
7mm is not enough.
No pinout or wiring detail beyond NPN-NO, 2-Wire, no mechanical drawing beyond M18 threaded cylinder, no target specification behind the 7mm sensing distance, and no load or output-current detail. Those gaps decide cabinet wiring, bracket design, and input compatibility.
View the Win-Source product page for E2EF-QX7D1 2M.
Key Takeaways for Engineers & Buyers
- Block new BOM releases for E2EF-QX7D1 2M; lifecycle reads EOL despite one Active status field.
- Match the control input to NPN-NO, 2-Wire before reuse; that output choice decides wiring compatibility.
- Check machine timing against 100Hz response and fixture geometry against the 7mm sensing distance.