Omron E2EF-X7D1 2M sustaining only, not new design-in

E2EF-X7D1 2M Omron product image

10V to 30V supply, 7mm inductive range, M18 threaded body, -10°C to 70°C limits where it fits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 7MM CYLIND
Key electrical rangeOperating Temperature: -10°C ~ 70°C; Output Type: NPN-NO, 2-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 30V
Reported stock1 pcs reported — confirm on RFQ

The real constraint is lifecycle, not sensing distance

The constraint is availability. Lifecycle fields show EOL, Lifecycle Status also shows EOL, and Product Status says Active. For new design-in, that conflict does not change the call: the conservative read is still EOL, so this is a sustaining part, not a fresh release choice.

The sensor itself is easy enough to place on paper. E2EF-X7D1 2M is an industrial inductive sensor with 0.276" (7mm) sensing distance, a 10V ~ 30V supply window, NPN-NO, 2-Wire output, and a Cylinder, Threaded - M18 body with Cable Leads. Those details answer fit and interface questions, but they do not solve the bigger problem, because Stock Quantity is 1 and workbook_qty is 1, which turns any purchase into a stopgap move for an existing machine rather than a stable sourcing plan.

RoHS status is unsettled too. One compliance field says compliant, another says non-compliant, so EU RoHS stays unresolved until the manufacturer declaration is checked.

The weak point is speed; the strong point is plant-floor fit

100Hz is the weak point. It sets the event-rate ceiling, so fast target counting is off the table before mounting even enters the discussion, and a quick mechanism or short target window can push E2EF-X7D1 2M into missed transitions where a slower station would still be fine.

The stronger case is basic industrial presence sensing. The 0.276" (7mm) distance keeps it in short-range inductive work, while the Shielded construction and M18 threaded cylinder suit flush-mounted metalwork with a defined sensing face. IP67 and a Stainless Steel body help on the mechanical side, and -10°C ~ 70°C is the ambient ceiling for the installed location.

10V to 30V decides the control-panel side

10V ~ 30V gives it a workable place on common industrial DC control rails. It is still only the listed operating range, and it says nothing about surge tolerance, brownout behavior, or miswire survival.

NPN-NO, 2-Wire narrows the fit in a useful way. E2EF-X7D1 2M belongs in control schemes already built for that output style, not on inputs expecting a different sensor interface.

Cable Leads matter too. This isn't a quick-swap connectorized drop-in, so service access and harness routing need to match the machine already in service.

What is the one buying move here?

Need one to keep a line running? Buy the remaining unit only for an existing installation. Quantity is 1, and the lifecycle call is EOL.

The missing details are the ones that close risk

Key details are missing.

There is no pinout detail beyond NPN-NO, 2-Wire, no mechanical drawing beyond M18 threaded cylinder, no cable length detail beyond the 2M in the part number, and no switching current or load specification showing what input burden E2EF-X7D1 2M can drive.

Those gaps decide interchangeability in an existing machine. Without the drawing, pin assignment, and output load limits, you can place E2EF-X7D1 2M in the right sensor class, but you can't close the final fit check.

View the Win-Source product page for E2EF-X7D1 2M.

Key Takeaways for Engineers & Buyers

  • Freeze E2EF-X7D1 2M for existing builds only; lifecycle reads EOL and stock is 1.
  • Match the control input to NPN-NO, 2-Wire before release; that output choice closes the wiring scheme.
  • Keep the application inside 10V to 30V and -10°C to 70°C; those are listed limits, not margin targets.