Omron E2EH-X3D1-T 5M active for new design-in

E2EH-X3D1-T 5M Omron product image

10V ~ 32V supply, 3mm shielded M12 body, 500Hz response, 0°C ~ 100°C, IP67 and IP69K

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBox
Core functionSENSOR PROX INDUCTIVE 3MM CYLIND
Key electrical rangeOperating Temperature: 0°C ~ 100°C; Output Type: NPN-NO, 2-Wire, No Polarity; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 32V
Reported stock1 pcs reported — confirm on RFQ

Not for long range sensing; good for sealed close-in detection

If you need stand-off, this is the wrong sensor. E2EH-X3D1-T 5M has a listed sensing distance of 0.118" (3mm), so it belongs in fixtures where the target comes to the sensor, not in layouts trying to bridge loose tolerances or wide air gaps.

Its value is more specific than broad. You get inductive sensing in a shielded M12 threaded cylinder with a stainless steel body, cable leads, and IP67, IP69K sealing. That points to dirty or washdown machinery where survival matters as much as detection. Active lifecycle and EU RoHS support new design-in, though stock quantity 1 keeps supply risk in view.

The weak point is reach; the strong point is rail tolerance

Three millimeters is the first limit to respect. It is a sensing ceiling, not a promise that every target and mounting condition will switch comfortably at that point.

The stronger number is the 10V ~ 32V supply range. That gives E2EH-X3D1-T 5M room on common industrial control rails and rules it out for lower-voltage sensor power schemes. Response frequency at 500Hz is the other practical filter: fine for ordinary machine position feedback, not a blank check for every high-speed counting job. Mount it close.

The numbers force a machine-mounting decision

The constraint is physical before it is electrical. A Cylinder, Threaded - M12 package with shielded construction and a 0.118" (3mm) sensing distance means the target path has to be controlled and the bracket has to hold that gap repeatably through vibration, contamination, and thermal movement; once the target drifts outside that small window, the rest of the part's strengths stop helping.

Temperature range sharpens that decision. The listed 0°C ~ 100°C operating temperature is exactly that: an operating range, with 100°C as the upper limit and 0°C as the lower one. That makes E2EH-X3D1-T 5M easier to justify near warm tooling or enclosed equipment than sensors with a lower top end, while still excluding cold-start environments below 0°C.

Environmental sealing rounds out the fit. IP67, IP69K and a stainless steel body point to equipment that gets sprayed, wiped down, or lives around coolant and debris. The package and sealing are doing real work here, because a short-range sensor only pays off when the machine can keep the target where it belongs and the environment does not take the sensor out first.

The output style narrows the use case further. NPN-NO, 2-Wire, No Polarity is not a universal answer for PLC input cards, so E2EH-X3D1-T 5M fits where that wiring style is already accepted, not where the controls standard expects something else. The LED indicator helps during setup and fault finding, but it doesn't close the remaining integration gaps.

Buy it for a running plan only if supply is lined up

And that is the real commercial constraint. The part is Active, but listed stock quantity is 1, so E2EH-X3D1-T 5M should not go into a build plan on the strength of on-hand quantity alone.

Use it when the mechanical and environmental fit is already right, then secure incoming supply before releasing it broadly across a line. Box packaging is ordinary; the meaningful issue is that one unit on hand does not support production continuity.

What the listing still does not answer

1 unit in stock is clear, but integration details are not. Missing items include pinout, mechanical drawing, load current details, and switching diagrams.

View the Win-Source product page for E2EH-X3D1-T 5M.

Key Takeaways for Engineers & Buyers

  • Hold E2EH-X3D1-T 5M for 10V ~ 32V sensor rails only; it does not close lower-voltage control schemes.
  • Use the 3mm sensing distance as the mechanical trip ceiling and keep fixture tolerances honest.
  • Treat stock quantity 1 as the immediate line risk; place only against confirmed incoming supply.