Omron E2EH-X7C1 2M active, but stock is the issue

E2EH-X7C1 2M Omron product image

10V ~ 32V supply, 7mm shielded inductive sensing, M18 threaded body, 0°C ~ 100°C operation

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBox
Core functionSENSOR PROX INDUCTIVE 7MM CYLIND
Key electrical rangeOperating Temperature: 0°C ~ 100°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 300Hz; Voltage - Supply: 10V ~ 32V
Reported stock0 pcs reported — confirm on RFQ

Active part, unavailable today

Active, but blocked today.

E2EH-X7C1 2M is clearly Active, and the lifecycle signals agree, so there is no status conflict around a fresh design. The real constraint is stock quantity 0.

That matters more than the headline specs. For an existing production build, secure material first or this part stalls the line. For a new platform, the lifecycle is fine and EU RoHS is fine, but an Active flag does not change zero availability.

Will it fit the control rail and the target gap?

Will it run on 10V ~ 32V and detect reliably at 0.276" (7mm)?

Those are the first checks because they settle basic electrical and mechanical fit before body material or the LED enters the conversation.

The 10V ~ 32V supply range sets the allowed operating window. It places the sensor on industrial DC rails that stay inside that band, but it does not answer noise margin, output loading, or startup behavior because those limits are not listed here. The 0.276" (7mm) sensing distance is the other hard filter. If the bracket stack, target travel, or guard spacing needs more reach, E2EH-X7C1 2M is out. If the detection point sits inside that distance and you need a shielded inductive sensor in an M18 threaded cylinder, the basic fit is there.

Not for fast counting; fine for harsh washdown sensing

Not for high-speed event capture.

A 300Hz response frequency puts E2EH-X7C1 2M in ordinary position sensing and presence detection, not in jobs where missed transitions turn into field failures.

It fits industrial hardware that wants a shielded inductive sensor with an M18 threaded body, stainless steel construction, cable leads, and ingress protection called out as IP67 and IP69K. That combination points to mounted machine sensing where contamination and washdown matter as much as the electrical interface. The 0°C ~ 100°C operating temperature matters too, but treat it as the stated operating span; it does not answer thermal drift, hot-soak behavior, or cable performance because those details are absent.

300Hz is the real application limit

300Hz is the real cutoff.

Buyers often look at the 7mm sensing distance first, but the response frequency is what decides whether E2EH-X7C1 2M quietly does its job or becomes the sensor that misses edges once the machine speeds up, especially in sequences where short intervals between state changes carry the whole control decision.

At 300Hz, this part fits straightforward presence detection, end-of-travel confirmation, and moderate-rate indexing. It does not fit rapid tooth counting, fine pitch target tracking, or any sequence where the controller depends on very short intervals between state changes. Get that wrong and the symptom is not subtle; it shows up as intermittent misses that look like logic faults until someone traces them back to the sensor limit.

The rest of the listed fit supports the same reading. NPN-NO, 3-Wire means the control side must expect an NPN normally open output, and cable leads make this a fixed-lead installation choice rather than a connectorized swap-in. The M18 threaded cylinder and shielded construction help with mounting discipline and target localization, but they do not rescue an application that already outruns 300Hz.

What the listing still doesn’t answer

The weak point is detail.

You still need the pinout or lead assignment, the mechanical drawing, and load or output-current limits to finish a release on E2EH-X7C1 2M.

View the Win-Source product page for E2EH-X7C1 2M.

Key Takeaways for Engineers & Buyers

  • Match the control input to NPN-NO, 3-Wire before releasing E2EH-X7C1 2M.
  • Hold layout for an M18 threaded cylinder and cable-lead termination.
  • Do not schedule builds against E2EH-X7C1 2M until stock moves off 0.