Omron E2EM-X2B2-M1 discontinued for sustaining only

E2EM-X2B2-M1 Omron product image

10V to 40V supply, 2mm sensing, M8 threaded body, and -40°C to 85°C operating limits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 40V
Reported stock1 pcs reported — confirm on RFQ

Discontinued first, usable only if the line already exists

The weak point comes first: E2EM-X2B2-M1 is discontinued, and the lifecycle fields also show an EOL signal. The useful part is that the electrical and mechanical picture is still specific enough to show where it fit, so this is a sustaining part rather than an unknown one.

That settles the new-design question. Don’t start with E2EM-X2B2-M1. For existing production, use it only to cover a defined service need or a short manufacturing gap while migration work starts. EU RoHS is compliant, so compliance is not the blocker. Lifecycle is.

Wrong for long-range sensing, right for tight metal targets

Not for generous stand-off. The listed sensing distance is 0.079" (2mm).

It fits close-in metal detection on compact fixtures: inductive, shielded, in a threaded M8 cylinder with connector termination. The LED helps setup, but 2mm keeps mounting tolerance tight.

The numbers force a narrow installation window

The constraint is a narrow installation window. Every key number here limits fit before it says much about performance.

A 10V ~ 40V supply range covers common industrial control rails, but it does not answer output current, voltage drop, or load-type margin. That closes the supply question without closing the input-interface question.

The 0.079" (2mm) sensing distance is a hard fit limit, not an operating point you can spend freely on bracket error, target variation, and contamination. Get that wrong and the field symptom is intermittent detection, not graceful degradation. Shielded construction points to flush-style mounting behavior, where the mechanical envelope is controlled more tightly than with an unshielded body.

The time-domain ceiling matters too. A 1.5kHz response frequency works for many machine sensing jobs, but it remains a listed limit. If line speed or part pitch is aggressive, that is where missed counts begin. The -40°C ~ 85°C operating temperature and IP67 ingress protection make E2EM-X2B2-M1 credible around washdown and outdoor cabinet conditions, while the stainless steel body helps where plated barrels get chewed up by handling or coolant.

In short, E2EM-X2B2-M1 fits compact industrial metal sensing in rough surroundings, but only when the machine can live inside a 2mm detection window and a 1.5kHz ceiling.

One unit listed changes the buying plan

1 unit is the decisive figure. With stock quantity listed as 1 and package shown as Bulk, this is not a recoverable running source.

Buy only to clear an immediate failure or keep an existing machine moving while the redesign is underway. E2EM-X2B2-M1 should not remain on any open-ended build plan.

The missing details are the ones that close the interface review

And that is where the page stops. The listing does not give pinout, connector wiring, output current, or a mechanical drawing, and those items decide whether E2EM-X2B2-M1 drops into an existing harness and input card without rework.

It also omits any switching diagram or load detail for the PNP-NC, 3-Wire output. That gap matters more than the LED indicator.

View the Win-Source product page for E2EM-X2B2-M1.

Key Takeaways for Engineers & Buyers

  • Block new BOM releases on E2EM-X2B2-M1; lifecycle is Discontinued.
  • Check controller input logic against PNP-NC, 3-Wire before any last-time buy.
  • Reserve the single listed unit only for a line stop or failure analysis.