Omron E2EM-X4B1 2M discontinued, sustaining use only

E2EM-X4B1 2M Omron product image

10V ~ 40V supply, 4mm shielded range, M12 threaded body, -40°C ~ 85°C operating limits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 4MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 40V
Reported stock1 pcs reported — confirm on RFQ

Wrong for new builds, still usable in a running line

Wrong for a new machine. E2EM-X4B1 2M is marked Discontinued, and the lifecycle conflict only moves between EOL and Discontinued, never back to Active, so the conservative call is sustaining use only.

It still fits an existing build that already expects a shielded inductive sensor with PNP-NO, 3-Wire output, cable leads, and a threaded M12 cylindrical body. EU RoHS is listed, so compliance is not the blocker. Availability is stock 1: enough to cover a line failure, not enough to reopen a released design around E2EM-X4B1 2M.

The real constraint is fit at the rail and the target

The constraint is narrow: the machine rail and the target position both have to land inside a small set of fixed numbers, and if either one misses, the sensor stops being a clean drop into the design.

The listed 10V ~ 40V supply range is an operating window, not a nominal point, so treat 40V as the ceiling. That settles basic rail fit for many industrial DC systems, but it does not answer output loading, inrush, or protection behavior because those figures are not shown here.

The next gate is the 0.157" (4mm) sensing distance. In practice, that puts E2EM-X4B1 2M in brackets and fixtures that can hold a short, repeatable approach without target wander eating the margin. Miss that mechanical stack, and the symptom in the field is usually intermittent detection that looks mechanical before anyone blames the electrical side.

Response frequency is 500Hz. Useful, yes. Still, it is only one timing number, and without on-delay, off-delay, or hysteresis, a tight detection timing budget stays open.

Environmental fit is easier to like than lifecycle fit. The -40°C ~ 85°C operating temperature and IP67 ingress protection support dirty industrial mounting and harsh ambient conditions, but they do not answer chemical exposure, cable flex life, or connector sealing, especially since this version ends in cable leads rather than a field-replaceable connector.

4mm decides the mechanical conversation

4mm decides it. With shielded construction and a Cylinder, Threaded - M12 body, E2EM-X4B1 2M suits flush-mount metalwork and compact fixtures better than open standoff sensing, but not positions where bracket deflection or target wander consumes that short distance.

What the listing still does not tell you

And that missing detail matters more than another restatement of the package. The listing gives no pinout detail beyond PNP-NO, 3-Wire, so wiring review still needs the pinout. It also omits load current, current consumption, and short-circuit behavior, the numbers that decide PLC input compatibility and fault handling.

Two more gaps keep timing and installation from closing quickly: no hysteresis figure, and no dimensional drawing beyond M12 threaded cylinder. For E2EM-X4B1 2M, those omissions separate a quick sustaining buy from a clean signoff on a machine change.

View the Win-Source product page for E2EM-X4B1 2M.

Key Takeaways for Engineers & Buyers

  • Block new BOM releases on E2EM-X4B1 2M; lifecycle is Discontinued.
  • Check the machine rail against the 10V ~ 40V supply window before touching I/O wiring.
  • Confirm the target can be held inside the 0.157" (4mm) sensing distance in the installed bracket.