10V ~ 30V supply, 5mm shielded M18 inductive sensor, 70Hz response, -10°C ~ 55°C ceiling
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: -10°C ~ 55°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 70Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Wrong for new builds, usable only where it is already qualified
Wrong for a new build. The lifecycle calls split between EOL and Discontinued, but neither supports a fresh release, and stock is 0. That leaves this as a sustaining-only choice for existing production that already depends on the exact switching behavior and mechanical form.
Where it still fits is much narrower: a shielded inductive proximity sensor with 0.197" (5mm) sensing distance, NPN-NC 3-wire output, cable leads, and a threaded M18 cylindrical body in nickel-plated brass. That set of traits works in machines that already have the mounting boss, cable routing, and input logic for this exact sensor style; change any one of those, and it stops being a drop-in decision.
EU RoHS status is not clean either. One field says compliant, while another says non-compliant, so the manufacturer record needs to settle it before any compliance call is made.
The real ceiling is speed, not supply rail
The limiting number is 70Hz. That sets this sensor on slow position checks, not faster count-and-detect work.
The 10V ~ 30V supply range answers rail compatibility, not field survivability.
And the package tells you where it can live
And the mechanical side narrows it further. The M18 threaded cylinder and shielded construction make the fit call: this belongs in metalwork laid out for a barrel sensor, with a controlled sensing face and a short target distance, not on a compact PCB assembly or anywhere a flush cable exit becomes the real packaging problem.
Ingress protection is listed as IP67 with NEMA 1,3,4,6,12,13, which matters for splash, dust, and enclosure expectations. It does not answer chemical compatibility, cable flex life, or connector serviceability, because the part is cable-lead terminated and the listing stops there. The operating temperature of -10°C ~ 55°C is an ambient ceiling, not coverage for a hot cabinet or an outdoor winter install.
Weak availability, but the bigger problem is missing detail
0 units is the immediate stop. Even on an existing line, this is not something to schedule around unless stock is already in house.
The stronger technical problem is missing detail: no pinout or lead assignment, no dimensional drawing beyond M18 cylindrical form, no load current detail for the NPN-NC output, and no switching diagram or timing detail beyond 70Hz. Those gaps decide whether a line-down replacement is safe.
View the Win-Source product page for E2EV-X5C2.
Key Takeaways for Engineers & Buyers
- Block new BOM releases on E2EV-X5C2; lifecycle is Discontinued and stock is 0.
- Check the control input against NPN-NC, 3-Wire before touching an existing harness.
- Confirm the machine can live with 70Hz response and 0.197" (5mm) sensing distance.