Omron E2EW-QX10B3T18 2M: Active, but hold for RoHS

E2EW-QX10B3T18 2M Omron product image

10mm sensing distance, 2Hz response frequency and an M18 threaded body set the fit.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Active status does not settle this sensor's RoHS conflict

Purchase release stays on hold. All listed lifecycle signals for E2EW-QX10B3T18 2M say Active, making it a candidate for new design-in rather than a sustaining-only choice. The compliance field says RoHS Compliant; the specifications say RoHS Non-Compliant. Resolve the EU RoHS conflict before qualification. Active status doesn't settle it.

A 10mm reach and 2Hz response narrow the target job

Reach and response speed limit the target job. The listed 10mm sensing distance is a ceiling, not a guaranteed trip point for every target, so placing a target at that limit risks missed detections even when the stated reach appears to match the gap. The 2Hz response frequency makes fast target counting a poor fit, but it is not a latency specification. E2EW-QX10B3T18 2M belongs where the target event rate leaves room against that figure.

The 10V to 30V supply range rules out rails outside its stated bounds. The 0°C to 85°C operating-temperature range excludes colder starts and hotter locations. Its PNP-NC/NO, 3-Wire output requires a receiving input wired for the selected output behavior; matching the supply range alone does not settle that interface choice.

M18 mounting makes cable termination a build decision

M18 sets the threaded mounting choice. Cable leads determine how the assembly is terminated; the Box package isn't evidence of a connector. Specify the mounting and termination on the build documentation.

Fixed-position sensing fits; fast counting does not

Fast target counting is the wrong job for this shielded inductive sensor. A fixed-position presence check is more plausible where its threaded body can be mounted facing the intended target.

The listing has no target-dependent sensing-distance curve or output-load current limit. It also lacks a wiring diagram for the PNP-NC/NO leads and a mechanical drawing. Target clearance and input load remain open, as does physical installation.

View the Win-Source product page for E2EW-QX10B3T18 2M.

Key Takeaways for Engineers & Buyers

  • Check the intended target gap against the listed 10mm sensing-distance ceiling.
  • Compare target event frequency with the listed 2Hz response frequency.
  • Resolve the contradictory RoHS entries before releasing the build.