10mm sensing in an M18 body; the RoHS entries conflict.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Active status supports design-in; RoHS does not yet
Design-in remains conditional. The lifecycle entries for E2EW-QX10B3T18 5M agree on Active, so status alone does not confine it to sustaining designs. The materials entries disagree: the compliance field says RoHS Compliant, while the specifications say RoHS Non-Compliant. Resolve that conflict before releasing an EU RoHS build. Active status cannot settle a materials declaration.
The 10mm sensing distance needs a target trial
10mm is the listed sensing distance, not a promise of detection at that gap for every metal target. Trial the actual target and mounting before settling the target-to-face spacing. The shielded, threaded M18 body sets the mounting format.
The supply range and output must match the controller
The gap won't settle the wiring, either. The 10V to 30V supply range bounds the rail choice; 30V is its listed upper limit, not a normal operating target. PNP-NC/NO, 3-Wire determines the controller input arrangement. A controller wired for another output cannot accept this sensor unchanged. The listed 2Hz response frequency rules out treating it as a fast event counter but does not establish whether a particular short event will be captured.
An M18 machine fixture fits better than a board
Nonmetal targets are the wrong job for this inductive sensor. A metal target at a machine fixture is the plausible assignment. Its stainless-steel, IP67 body mounts by the threaded M18 housing, with cable leads routed to the controller. It is not a PCB-mounted switch. The 0°C to 85°C operating range excludes installations outside those temperatures; IP67 does not extend that range.
Missing application figures still hold up release
Application detail is thin, despite the specified mounting format and output type. The listing lacks sensing-distance curves for the actual target and mounting, a response-time specification for the event rate, an output load-current rating for the connected input, and a dimensioned drawing to clear the fixture and cable exit. The listed sensing distance and response frequency don't answer those questions.
Box is the stated packaging format. Keep E2EW-QX10B3T18 5M with cable leads on the BOM and arrange the installation around that termination. A connectorized configuration isn't interchangeable without a change to the wiring plan.
View the Win-Source product page for E2EW-QX10B3T18 5M.
Key Takeaways for Engineers & Buyers
- Resolve the contradictory RoHS entries before EU RoHS release.
- Trial the 10mm sensing distance against the actual metal target.
- Match the 10V to 30V supply range and PNP-NC/NO, 3-Wire output to the controller.