Omron E2EW-QX10C118 5M: Active, with RoHS unresolved

E2EW-QX10C118 5M Omron product image

10mm sensing distance, 2Hz response frequency, 10V ~ 30V supply, M18 threaded body.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Active status supports a new design, but RoHS does not clear

Even so, Active status makes E2EW-QX10C118 5M a new-design candidate rather than a part confined to sustaining work. The lifecycle signals agree. The compliance fields do not: one says RoHS Compliant, while the specification says RoHS Non-Compliant. Don't mark this BOM line EU RoHS compliant until that contradiction is resolved; it can hold up a regulated build even when the sensor fits the machine.

The sensing and supply numbers set different boundaries

Target spacing and event rate constrain placement and timing. The listed 10mm sensing distance is a starting point for positioning the target, not a guarantee that every target will switch at that gap. The 2Hz response-frequency figure gives no support for a faster event stream; a machine counting rapid passes needs timing evidence before this sensor goes on the drawing.

The 10V ~ 30V supply range sets the rail boundary. Its 30V end is a ceiling, not a recommended setpoint, while 10V is the lower limit. A supply outside that range rules out the electrical fit regardless of the mounting.

Temperature is stated; switching detail is not

0°C ~ 85°C is the listed operating-temperature range. An installation below 0°C falls outside it despite the stainless-steel body. No target-material sensing curve, switching response timing, or cable-lead wiring diagram is listed. Those details remain open for the datasheet to settle.

What should the assembly order specify?

Cable leads or a connector? Cable Leads is the listed termination; Box describes packaging, not the electrical connection. Put the cable termination on the assembly order so a connector assumption doesn't stop installation.

An M18 machine sensor, not a PCB sensing element

This belongs on a machine bracket. The M18 threaded cylinder and shielded inductive sensing face point to a fixed detection position with controlled target presentation, rather than a sensor placed on a PCB. NPN-NO, 3-Wire must match the machine input. A different expected output behavior is a circuit mismatch, not a mounting problem.

The IP67 rating and stainless-steel body support exposed industrial placement, but they do not establish how the assembled cable exit will be protected. The LED offers local indication during setup. It cannot show whether the actual target switches at the position and speed the process requires; that takes a trial with the target.

View the Win-Source product page for E2EW-QX10C118 5M.

Key Takeaways for Engineers & Buyers

  • Resolve the conflicting RoHS fields before approving a regulated build.
  • Check whether 2Hz supports the machine's event rate.
  • Put M18 threaded mounting on the mechanical drawing.