Omron E2EW-QX10C218 2M: Hold new design-in over RoHS

E2EW-QX10C218 2M Omron product image

10mm sensing distance, 2Hz response ceiling, M18 housing; conflicting RoHS entries hold new design-in.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 10MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

10mm reach cannot settle the RoHS conflict

10mm is the listed sensing distance, not a promise for every target or mounting geometry. E2EW-QX10C218 2M is marked Active throughout the lifecycle entries, so obsolescence is not the reason to hold a new design-in. The hold comes from compliance: one field says RoHS Compliant, while the specifications say RoHS Non-Compliant. Resolve that conflict before releasing a new BOM. Active status leaves the sensor in consideration for existing production, but it cannot settle whether the part meets an EU RoHS requirement.

A 2Hz ceiling rules out fast target counting

This isn't a fast target counter. The listed 2Hz response frequency is a ceiling, not evidence that faster events will register. The shielded inductive sensor and threaded M18 cylinder point instead to a fixed metal-target station with a low enough event rate.

M18 mounting fits only if the rail and input fit too

Even at that low rate, the input has to accept an NPN-NC, 3-Wire output; an input expecting a different signal will read the wrong state. The 30V upper supply limit rules out a rail that can exceed it, while the 10V lower bound leaves a sagging rail outside the listed range; neither bound settles permissible ripple. The 0°C ~ 85°C operating range excludes freezing starts and hotter enclosure conditions.

The stainless-steel body and IP67 ingress rating suit an exposed industrial mounting point, but IP67 does not establish how the cable-lead termination holds up to a particular washdown. Specify cable leads on the BOM so E2EW-QX10C218 2M is not mistaken for a connectorized drop-in.

The output and mounting still need drawings

The wiring diagram is missing. No output load-current limit is listed for the NPN-NC, 3-Wire output, either. Those details decide whether the input circuit can be driven and how the leads connect. An M18 mounting drawing and target-dependent sensing-distance curves are also absent, leaving mechanical clearance and detection margin open.

View the Win-Source product page for E2EW-QX10C218 2M.

Key Takeaways for Engineers & Buyers

  • Resolve the conflicting RoHS entries before releasing a new BOM.
  • Check event rate against the 2Hz response-frequency ceiling.
  • Keep the supply rail within the listed 10V ~ 30V bounds.