Omron E2EW-QX12B218 5M: Active, but RoHS status conflicts

E2EW-QX12B218 5M Omron product image

12mm sensing, 2Hz response, M18 threaded body; 30V supply ceiling.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M18
Core functionSENSOR PROX INDUCTIVE 12MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Does 12mm reach matter if the target passes too quickly?

12mm is the listed sensing distance. It does not promise switching with every target at that gap. For E2EW-QX12B218 5M, trial the target material and mounting geometry at the intended machine position before fixing the bracket, rather than treating the listed distance as a guaranteed switching point. The shielded, stainless-steel M18 threaded cylinder calls for a threaded machine mount, not a flush panel cutout guessed from the sensing distance.

The 2Hz response frequency may end the discussion sooner. It is not a switching-time specification. A briefly passing target could be within range yet go unseen by the control input; test the event at the intended machine speed before committing the bracket.

Active lifecycle does not settle the RoHS conflict

Active does not settle compliance. E2EW-QX12B218 5M can be considered for a new design-in because its lifecycle signals agree, but one RoHS entry says compliant and another says non-compliant. Hold an EU RoHS-dependent release until a manufacturer declaration resolves the conflict.

The 30V ceiling and PNP-NC output set the electrical boundary

30V is the supply ceiling, not a working setpoint; 10V is the lower limit. A rail outside those bounds rules out the part before sensing distance matters. The PNP-NC, 3-Wire output must also match the control input’s expected polarity and normal state, or a detected target can produce the wrong machine signal.

The 0°C ~ 85°C operating-temperature range excludes locations below its lower bound and puts enclosure heat on the mounting checklist. IP67 is the sensor’s listed ingress rating; it says nothing about how the cable leads are terminated in the installation.

Cable leads require a harness plan, not a connector assumption

A connector-only harness won’t work with cable leads. This sensor needs a termination plan at the control end before E2EW-QX12B218 5M goes on a running line.

The wiring diagram is absent, so PNP-NC, 3-Wire does not identify the conductors. The M18 mounting drawing and output load-current limit are absent too. Those details determine whether the harness, bracket and input can be released.

View the Win-Source product page for E2EW-QX12B218 5M.

Key Takeaways for Engineers & Buyers

  • Test the 12mm sensing distance against the actual target.
  • Check whether 2Hz response can detect the passing target.
  • Resolve the conflicting RoHS entries before approving the BOM.