30V supply ceiling, 12mm listed sensing distance, M18 threaded body, 0°C ~ 85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 12MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
An active M18 sensor, if the application fits
Even so, Active is only a starting point: the lifecycle fields agree, so E2EW-QX12C118 5M is a candidate for new design-in, but the installation must meet its electrical and mechanical limits. The listed supply runs from 10V to a 30V ceiling; those bounds let you screen the rail, not approve its transients. Its NPN-NO, 3-Wire output must suit the controller input. Otherwise, the sensor may detect a target without producing a usable signal.
The 12mm sensing distance is a starting point for metal-target placement, not a guarantee for every target. Its shielded stainless-steel body has an M18 thread; confirm that the machine mount accepts it. The 0°C ~ 85°C operating-temperature range rules out installations expected to run below its lower bound or above its upper bound.
Can the RoHS conflict be cleared before purchase?
Can I put E2EW-QX12C118 5M on a RoHS-controlled BOM? Not yet. The compliance field says RoHS Compliant; the specifications say RoHS Non-Compliant. Get a manufacturer declaration that settles the contradiction before approving the part. Active lifecycle status does not settle material compliance.
The 2Hz response frequency needs a motion check
2Hz is the listed response frequency. It does not establish whether a moving target will register in your machine; test the actual target and motion, since no response-time waveform is listed.
The M18 body still needs mounting and wiring details
The interface isn't settled. Get the mechanical drawing to check clearance around the M18 thread and lead identification before wiring the cable to the controller. An output-current limit is absent, so the NPN-NO output cannot yet be checked against the intended input load. The cylindrical body description supplies none of those details.
View the Win-Source product page for E2EW-QX12C118 5M.
Key Takeaways for Engineers & Buyers
- Check the controller input against the NPN-NO, 3-Wire output.
- Test the actual metal target at the planned 12mm spacing.
- Resolve the conflicting RoHS entries before BOM approval.