2Hz response ceiling, 12mm sensing limit, 10V–30V supply bounds; M18 threaded body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M18 |
| Core function | SENSOR PROX INDUCTIVE 12MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Does the 2Hz ceiling rule out the intended event?
2Hz is the listed response-frequency ceiling. It suits slow presence checks, not a station where missed short events stop the line, though that figure alone doesn't specify a minimum detectable pulse. The 12mm sensing distance is a listed limit, not a promise that every target material will trip at that clearance; beyond it, the input may never change.
The supply listing sets a 30V upper ceiling and a 10V lower bound. Those numbers help screen the planned rail, but they don't settle voltage at the sensor after wiring losses. Timing and target placement decide this application before the stainless-steel body does.
The M18 body suits a mounted machine sensor, not a plug-in socket
That target must face a shielded, threaded M18 cylinder. The stainless-steel body and IP67 ingress rating support a machine-mounted location, while cable leads need a routing and termination plan rather than a plug-in sensor socket. The NPN-NC, 3-wire output calls for a compatible controller input: treating its normally closed signal as a normally open event would invert the machine response. The LED helps at the sensor, but it cannot establish switching timing.
Active status supports design-in; the RoHS conflict holds qualification
The 0°C to 85°C operating range limits placement: screen the machine environment, but don't assume the sensor enclosure stays within that range. The lifecycle status is consistently listed Active, so new design-in is reasonable on lifecycle grounds.
EU RoHS qualification remains unresolved. One field says compliant; the specification entry says non-compliant. Get the conflict resolved in writing before approving the exact BOM line. An Active lifecycle flag cannot settle material qualification.
The output is named, but the integration details are not
The wiring diagram, mounting drawing, and target-dependent sensing data are absent. The named NPN-NC, 3-wire output still lets you scope the controller input. Don't freeze wiring or target clearance from this brief.
View the Win-Source product page for E2EW-QX12C218 5M.
Key Takeaways for Engineers & Buyers
- Check the event rate against the 2Hz response-frequency ceiling.
- Keep the target within the listed 12mm sensing limit.
- Resolve the conflicting EU RoHS entries before approving the BOM line.