20mm sensing ceiling, 10V ~ 30V supply range, M30 threaded body; RoHS entries disagree.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 20MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Active status permits design-in, but RoHS needs an answer
Can this sensor go on a new machine BOM? E2EW-QX20B1D30 5M has lifecycle indicators that all say Active, so new design-in is defensible on lifecycle grounds. RoHS is the obstacle. The top-level field says compliant; the specification says non-compliant. For a BOM requiring EU RoHS compliance, get a reconciled manufacturer declaration before release, because those conflicting entries leave the status unresolved and neither one cancels the other.
Existing production has a separate practical constraint: Cable Leads termination. Keep that termination in the build instructions rather than assuming a plug-in connection when ordering the boxed sensor.
The 20mm reach does not promise detection at 20mm
Reach is conditional. Don't treat the listed 20mm sensing-distance ceiling as a guaranteed detection gap for every target. A design that depends on detection at that boundary needs target-specific evidence. The 2Hz response-frequency ceiling also rules out assuming the sensor will catch faster events; it supplies no switching-time figure.
The listed 10V ~ 30V supply range bounds supply selection, but it does not establish tolerance to transients outside that range.
M30 mounting and PNP-NO output fix the machine interface
Bracket placement is constrained by the M30 threaded body and the 0°C ~ 85°C operating range. The thread calls for a bracket suited to a cylindrical sensor. IP67 rates ingress protection; it doesn't address chemical exposure. Wire the PNP-NO, 3-Wire output to an input that accepts it, or a target may go undetected. Cable Leads put the connection method in the machine builder’s hands rather than at a sensor connector.
The mounting and sensing details still need drawings
The missing mounting drawing and wiring diagram are the weak point, though the M30 thread and PNP-NO, 3-Wire output establish where to start. The target-dependent sensing curve and output-load limit are also absent. Those items settle the bracket, detection gap, and input circuit before release.
View the Win-Source product page for E2EW-QX20B1D30 5M.
Key Takeaways for Engineers & Buyers
- Set the target gap against the 20mm sensing ceiling, not at it.
- Check that the control input accepts PNP-NO, 3-Wire output.
- Resolve the contradictory EU RoHS entries before releasing a regulated BOM.