Omron E2EW-QX20B230 5M: Active, but RoHS status conflicts

E2EW-QX20B230 5M Omron product image

20mm sensing distance, 10V–30V supply bounds and M30 body; RoHS status conflicts.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 20MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Active lifecycle, unresolved RoHS status

RoHS isn't settled: one entry says compliant, the other non-compliant. E2EW-QX20B230 5M is marked Active across the lifecycle fields, so it remains a candidate for new design-in, but hold release to a restricted-substance BOM until the conflict is resolved. The disagreement concerns material compliance, not evidence that the sensor is nearing end of life.

Supply and temperature bounds decide where it can run

The 10V to 30V supply bounds and 0°C to 85°C operating-temperature range set the installation limits. Check the controller rail against the supply bounds, but treat neither endpoint as a target setpoint or a guarantee against voltage dips at the cable end. The stated temperature range rules out colder starts and hotter mounting locations on these figures alone. The stainless-steel body and IP67 rating don't extend that range.

The M30 mount needs the right input logic

This belongs on fixed machinery. The M30 threaded cylinder needs a matching mount, while its PNP-NC, 3-wire output needs a controller input expecting that polarity. Treat it as normally open and the machine may read the wrong sensor state. Shielding is specified, but it does not establish detection margin for a particular target. The LED allows a local check, not proof of sensing distance in the installed bracket.

The 20mm claim still needs a target test

20mm is the listed sensing distance, not clearance to spend without testing the actual target. Test the target material, geometry and mounting arrangement together rather than assuming that distance holds for a different metal or a tight bracket. The listed 2Hz response frequency raises a separate timing question for moving features; without a target-speed or pulse-width envelope here, a missed transition could become a missed machine event.

The missing datasheet items are specific: target-material sensing curves, switching hysteresis, cable-lead wiring diagram and M30 dimensional drawing. They are needed to settle the sensing-margin, transition and installation questions left open by the short specification. Until then, E2EW-QX20B230 5M is a plausible sensor selection, not a validated trip point.

Box packaging leaves a cable-termination step

Does it come with a plug? It is packaged in a box and terminates in cable leads, not a stated plug. Add cable-lead termination to the build instructions before issuing the buy.

View the Win-Source product page for E2EW-QX20B230 5M.

Key Takeaways for Engineers & Buyers

  • Match the controller input to the PNP-NC, 3-wire output.
  • Test moving targets against the listed 2Hz response frequency.
  • Resolve the opposing RoHS entries before releasing E2EW-QX20B230 5M on a restricted-substance BOM.