E2EW-QX20B3T30 2M Omron product image

20mm sensing distance, 2Hz response, M30 thread, and 0°C to 85°C operating bounds.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 20MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Active lifecycle does not settle the RoHS conflict

The RoHS declarations conflict: one field says compliant, the other non-compliant. Lifecycle signals agree that E2EW-QX20B3T30 2M is Active, so lifecycle status supports a new design-in. EU RoHS sign-off must wait until the declarations are reconciled.

Can the cable leads join the existing line?

Will the cable leads fit the line's existing harness? This M30 threaded sensor comes in a box, not with a connector that can drop into a different termination scheme. For production builds, match the cable-lead termination to the assembly before committing E2EW-QX20B3T30 2M. The stainless-steel cylindrical body also has to fit the machine fixture; the package description doesn't give mounting dimensions.

The 2Hz response rules out fast detection

Fast-moving targets are the wrong job for a 2Hz response frequency. For slower metal-target position checks, the shielded inductive sensor has a listed 20mm sensing-distance ceiling, not a guarantee that every target will register at that gap. A missed target can mean a missed machine state. Establish target and mounting geometry before setting the switch point, and match the PNP-NC/NO, 3-Wire output to the input circuit. The output description does not state the load limit.

Supply and temperature bounds leave key details open

The 10V to 30V supply limits and 0°C to 85°C operating-temperature bounds constrain the installation, but neither range identifies a preferred setpoint. A supply outside its limits rules out the installation; a sensor location outside the temperature bounds calls for a different placement or part. IP67 is listed, but leaves exposure questions at the mounting point.

The datasheet must supply the output load limit and pinout to close the input-circuit check. A mounting drawing is needed to settle fixture clearance, while target-dependent sensing information is needed to establish a reliable detection gap. Those details matter more than repeating the 20mm figure: without them, the electrical connection and mechanical fit remain open.

View the Win-Source product page for E2EW-QX20B3T30 2M.

Key Takeaways for Engineers & Buyers

  • Check the metal-target gap against the listed 20mm sensing distance.
  • Keep required switch events within the listed 2Hz response frequency.