Omron E2EW-QX20C130 5M: Active, RoHS status unresolved

E2EW-QX20C130 5M Omron product image

20mm sensing distance, 2Hz response frequency, M30 threaded body; RoHS entries conflict.

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageCylinder, Threaded - M30
Core functionSENSOR PROX INDUCTIVE 20MM CYL
Key electrical rangeOperating Temperature: 0°C ~ 85°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V

Active status leaves RoHS as the release question

Can E2EW-QX20C130 5M go into a new machine? On lifecycle grounds, yes: every stated signal says Active. The hold is compliance. One RoHS entry says compliant; another says non-compliant. Keep the new-design option open, but don’t release a compliance-dependent BOM until Omron confirms which entry applies.

The 20mm sensing claim starts the bracket, not finishes it

20mm is the stated sensing distance. It isn’t a guaranteed trip distance for every metal target. Target size and material remain unresolved, so setting the bracket at that distance without accounting for variation could leave parts undetected. The M30 threaded cylinder and shielded construction point to a fixed machine mount, but they do not establish the required clearance around the sensing face.

A 2Hz response figure limits the counting job

Timing limits the counting job: the 2Hz response-frequency figure rules out treating this inductive sensor as an unexamined fast-count input. The listed 30V ceiling and 10V lower supply limit bound rail selection, not permissible spikes; a nominal rail alone does not settle electrical fit. The 0°C to 85°C operating-temperature range rules out subzero installations. Near the upper end, temperature at the sensor matters more than the machine’s stated ambient. None of these figures specifies a detection waveform.

Cable leads and an NPN-NO output set the machine interface

A controller input that expects a sourcing sensor, or a harness built for a plug-in sensor, is the wrong starting point. The output is NPN-NO with a 3-Wire connection and cable leads. Select an input compatible with a sinking output, and plan the cable termination rather than assuming a connector is fitted.

For a fixed industrial sensing point, the M30 threaded stainless-steel body gives the mechanical layout a starting point. IP67 addresses ingress protection at the sensor, not the durability of a field splice. The LED offers local indication during setup; it cannot establish detection across all installed targets. Specify how the leads terminate before releasing the harness, or a sensor that fits the bracket could still stall assembly at the wiring bench.

The bracket and input schematic still need missing details

And that cable plan still needs a wiring diagram: lead identification and an output-current limit are absent. So are a target-material correction curve and mounting drawing. Those details must close the input schematic and bracket before the 20mm sensing claim becomes an installed detection point.

View the Win-Source product page for E2EW-QX20C130 5M.

Key Takeaways for Engineers & Buyers

  • Check the 20mm sensing gap against target material and mounting geometry.
  • Compare the 2Hz response figure with the machine’s event rate.
  • Resolve the conflicting RoHS entries before releasing the BOM.