20mm sensing distance, 2Hz response, 10V ~ 30V supply limits and M30 threaded body.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 20MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Can the 20mm sensing distance reach the target?
20mm is the listed sensing distance for E2EW-QX20C230 2M, so target spacing is the first design-in test. The figure does not establish detection of every metal target at that distance. Nor does reach solve a mounting problem: the M30 threaded cylinder needs a position that puts the target within range, and a sensor that cannot be mounted there is no fit at all.
The listed 10V ~ 30V supply range sets boundaries, not a preferred working setpoint. A rail outside those limits rules the part out; within them, the NPN-NC, 3-Wire output must still match the controller input. All lifecycle fields say Active. That supports new design-in, but it doesn't settle the conflicting RoHS entries, which remain a separate gate for a compliance-dependent release.
The RoHS entries block an unqualified release
That gate remains unresolved: the compliance field says RoHS Compliant, while the specification says RoHS Non-Compliant. Get a part-specific declaration from Omron before putting E2EW-QX20C230 2M on a RoHS-controlled BOM. Active lifecycle status can't reconcile the entries.
2Hz sets the pace of detection
2Hz is the listed response frequency. Detection events must be slow enough for that limit; rapidly passing targets could go undetected. The stated 0°C ~ 85°C operating-temperature range excludes positions below 0°C. Neither figure describes how the sensor responds to a particular target moving through its field. That matters before committing to an indexing mechanism.
Cable leads rule out a connector-first installation
Wrong for a harness designed around a mating sensor connector: this part has cable leads. It fits a threaded M30 mounting position where a shielded, stainless-steel inductive sensor and its listed IP67 protection suit the installation.
The remaining gaps are a wiring diagram, a mounting drawing, target-dependent sensing-distance curves and an output load-current limit. Those items determine the connection, mechanical fit and whether the controller input can be driven; the listed figures do not establish them.
View the Win-Source product page for E2EW-QX20C230 2M.
Key Takeaways for Engineers & Buyers
- Keep the supply within the listed 10V ~ 30V limits.
- Compare the 2Hz response frequency with the event rate.
- Resolve the conflicting RoHS entries before a compliance-dependent release.