20mm sensing distance, 10V–30V supply bounds, M30 thread, 0°C–85°C operating range.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Cylinder, Threaded - M30 |
| Core function | SENSOR PROX INDUCTIVE 20MM CYL |
| Key electrical range | Operating Temperature: 0°C ~ 85°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 2Hz; Voltage - Supply: 10V ~ 30V |
Does the 20mm reach justify a new design?
20mm is the stated sensing distance, not a guaranteed gap to every target. All lifecycle fields mark E2EW-QX20C230 5M Active, making it a new-design candidate. RoHS remains unresolved: one field says Compliant, the other Non-Compliant.
The 30V supply ceiling is not a nominal rail
30V caps the listed supply range; it isn't a nominal rail. The lower bound is 10V. A machine supply outside those bounds rules the part out as listed, while the range says nothing about supply transients.
The 0°C to 85°C operating-temperature range supports an ambient check, not a claim about the sensor’s temperature inside an enclosure. Cold startup below 0°C is out of range.
A 2Hz sensor belongs on presence checks, not rapid counts
Rapid target counting is the wrong job here. At the listed 2Hz response frequency, short events can't be assumed to register. For slower metal-target presence checks, the shielded inductive head and stated 20mm sensing distance offer a plausible layout, provided the actual target works at the intended gap.
The M30 threaded cylinder needs a matching mounting location. Its stainless-steel body and IP67 ingress rating support use in exposed industrial equipment, though neither establishes chemical compatibility. E2EW-QX20C230 5M has an NPN-NC, 3-wire output; match that state and wiring to the controller input rather than treating it as a normally open sensor. Cable leads also leave a production decision: settle the harness termination before releasing the build.
What the M30 callout cannot settle
The mechanical drawing is missing, though the threaded-cylinder description establishes the broad mounting format. Get the drawing before cutting the bracket and the cable wiring diagram before finalizing termination. The 20mm sensing-distance claim needs its target conditions, while the 2Hz response figure needs test conditions before it can settle event detection.
View the Win-Source product page for E2EW-QX20C230 5M.
Key Takeaways for Engineers & Buyers
- Match the 2Hz response frequency to the target event rate.
- Set up the harness and controller input for cable leads and NPN-NC, 3-wire output.
- Resolve the conflicting RoHS entries before approving the BOM.